Antaira Technologies - Industrial Wireless Access Points
ARS-7235-5E-AC Series - Hardware Manual - v1.0
2.8 Wireless Antenna
The 2.4GHz/5GHz antennas are connected with SMA connectors. Other external antennas can be used.
2.9 Wiring the Power Inputs
Caution:
Please follow the steps below when inserting the power wire.
Attention:
Veuillez suivre les étapes ci-dessous lors de l'insertion du câble d'alimentation.
1. Insert the positive and negative wires into the PWR1 (V1+, V1-) and PWR2 (V2+, V2-) contacts on the
terminal block connector as shown below in
Figure 2.6
.
Figure 2.6 - Power Terminal Block
2.
Tighten the wire-clamp screws to prevent the wires from loosening, as shown below in
Figure 2.7
.
Figure 2.7 - Power Terminal Block
Caution:
Only use copper conductors,
125°C
, tighten to
5 lbs.
The wire gauge for the terminal block should range between
18~20 AWG
.
Attention:
Utilisez uniquement des conducteurs en cuivre,
125°C
, serrez à
5 lb.
Le calibre des fils du bornier doit être compris entre
18
et
20 AWG.
8