ENGLISH
112
Indoor unit & control panel
It is recommended to install the indoor unit next to or
near the boiler room. Consult a plumber about the best
location for the unit to ensure optimal installation to
your existing hydronic system. Flexible hoses are
recommended for plumbing connections for the indoor
unit.
The control panel can be placed anywhere in the
house. However, if you want to control the unit at room
temperature, we recommend placing it in the room
where it is most important to maintain the required
temperature.
Outdoor unit
The outdoor unit consists of two wall brackets,
four vibration dampers and mounting bolts for
masonry and concrete walls. The outdoor unit
has pre-fitted pipe sections with screw fittings
(non-return valves).
Installation kit
The installation kit consists of two gas-filled
pipes, drainage hose, sealant, diffusion tape, 2
pipe insulation sections, cable ties and electrical
cable
with
connector
arrangement
for
connecting the indoor unit to the outdoor unit.
Note that the drainage hose must only be used
for air/air heat pumps and therefore not for
air/water.
NOTE:
Do not remove the plastic plugs on the
pipe sections until the installation of the pipes
has begun.
Summary of Contents for 416-086
Page 6: ...System A 127 System B 127 INSTALLATION 128 Installing the electric heater 128...
Page 9: ...SVENSKA 9 BESKRIVNING Innedel Utedel...
Page 10: ...SVENSKA 10 Man verpanel...
Page 13: ...SVENSKA 13 INSTALLATIONSTYPER DUBBELMANTLAD BEREDARE...
Page 14: ...SVENSKA 14 DIREKT P ETT VATTENBURET SYSTEM...
Page 15: ...SVENSKA 15 VIA V RMEK LLA MED SHUNT...
Page 16: ...SVENSKA 16 VIA TEKNIK MULTITANK...
Page 40: ...NORSK 40 BESKRIVELSE Innedel PO Utedel NENTER...
Page 41: ...NORSK 41 STYREPANEL...
Page 44: ...NORSK 44 DIREKTE P ET VANNB RNT SYSTEM...
Page 45: ...NORSK 45 VIA VARMEKILDE MED SHUNT...