SAFETY INSTRUCTIONS

Read the Operating Instructions carefully before use. 

Save these instructions for future reference. 

WARNING:

•  Failure to follow all the instructions and safety instructions can result in personal injury and/or 

material damage.

•  Disconnect the appliance from the mains before installation, maintenance and/or repair.
•  Installation, maintenance and/or repairs should be carried out by an authorised electrician and 

in accordance with these instructions.

•  The appliance is intended to be connected to 230 VAC 1-phase installations that comply with 

local regulations.

•  The appliance must be connected via a permanently installed automatic fuse with a minimum 

contact gap of 3 mm on all terminals.

•  Check before installation that the impeller och casing are undamaged.
•  There must be no foreign objects in the casing that could damage the fan blades.
•  The appliance must only be used as it is intended to be used and in accordance with these 

instructions. Do not make any modifications to the appliance.

•  The appliance is not intended to be used by persons (children or adults) with any form of 

functional disorders, or by persons who do not have sufficient experience or knowledge on how 
to use it, unless they have received instructions concerning the use of the appliance from 
someone who is responsible for their safety.

•  Keep children under supervision to make sure they do not play with the appliance.
•  Take the necessary precautions to prevent smoke, carbon monoxide and other flammable 

products from penetrating into the room through open flues or other fire safety devices. Make 
sure that the air supply is sufficient for correct combustion and adequate chimney draught,  
to prevent backward flow.

•  The transported medium must not contain dust or other solid particles, sticky substances  

or fibres.

•  Do not use the appliance in explosive environments, e.g. in the vicinity of flammable liquids, 

gases or dust, or in environments that contain toxic or harmful substances.

•  Do not block the openings on the appliance to attempt to direct or adjust the air flow.
•  Do not sit or stand on the appliance, or place any objects on it.
•  Follow all the directives and safety instructions for best results and service-life.
•  Recycle the product in accordance with local regulations when it reaches the end of its useful life.
•  Read these instructions carefully before installation and use, and save them for future reference. 

Summary of Contents for 414109

Page 1: ...nvisningen noggrant innan anv ndning Spara den f r framtida behov VENTILATIONSSATS SE EN VENTILATION KIT Operating instructions Translation of the original instructions Important Read the user instruc...

Page 2: ...tation Med forbehold om endringer Ved eventuelle problemer kan du kontakte v r kundeservice p telefon 67 90 01 34 www jula no Dbaj o rodowisko Nie wyrzucaj zu ytego produktu wraz z odpadami komunalnym...

Page 3: ...m inte har tillr cklig erfarenhet eller kunskap f r att anv nda den s vida de inte har f tt anvisningar g llande anv ndande av apparaten av n gon med ansvar f r deras s kerhet Barn ska h llas under up...

Page 4: ...mm Apparatens motor har tv varvtalsl gen min och max Luftriktningen i systemet ska motsvara pilen p fl kth ljet En indikeringslampa p frontpanelen visar driftstatus BETECKNINGAR I ELKRETSSCHEMA L Fasl...

Page 5: ...pplad fig 3 Vid horisontell montering ska luftkanalerna vara fria fr n kr kar minst 1 meter p vardera sidan om apparaten Vid vertikal montering ska en utv ndig huv monteras f r att skydda apparaten mo...

Page 6: ...SE 6...

Page 7: ...SE 7 16 17 18...

Page 8: ...SE 8 19 20 21 22 23 24 25...

Page 9: ...SE 9 28 27 26...

Page 10: ...tad med vatten och milt reng ringsmedel Se till att inte vatten tr nger in i elektriska komponenter Torka ytorna torra TRANSPORT OCH F RVARING Transportera apparaten i originalf rpackningen F rvara ap...

Page 11: ...uten tilstrekkelig erfaring med eller kunnskap i bruke det med mindre de har f tt anvisninger om bruk av apparatet av noen som er ansvarlig for deres sikkerhet Barn skal holdes under oppsyn slik at d...

Page 12: ...t skal kobles til luftekanal 100 mm Motoren i apparatet har to turtallsniv er min og maks Luftretningen i systemet skal tilsvare pilen p viftedekselet En indikatorlampe p frontpanelet viser driftsstat...

Page 13: ...seriekoblet fig 3 Ved horisontal montering skal luftekanalene v re fri for b yninger minst 1 meter p hver side av apparatet Ved vertikal montering skal en utvendig hette monteres for beskytte apparat...

Page 14: ...NO 14...

Page 15: ...NO 15 16 17 18...

Page 16: ...NO 16 19 20 21 22 23 24 25...

Page 17: ...NO 17 28 27 26...

Page 18: ...d vann og mildt rengj ringsmiddel Pass p at det ikke trenger vann inn i elektriske komponenter T rk overflatene t rre TRANSPORT OG OPPBEVARING Transporter apparatet i originalemballasjen Oppbevar appa...

Page 19: ...cego do wiadczenia lub umiej tno ci w zakresie obs ugi urz dzenia chyba e uzyskaj wskaz wki odno nie do obs ugi urz dzenia od osoby odpowiedzialnej za ich bezpiecze stwo Dzieci powinny przebywa pod n...

Page 20: ...ci obrotowej min i maks Kierunek przep ywu powietrza powinien by zgodny ze strza k na obudowie wentylatora Lampka kontrolna na panelu przednim pokazuje stan pracy OZNACZENIA W SCHEMACIE OBWODU ELEKTR...

Page 21: ...y monta u poziomym kana y wentylacyjne nie mog mie zagi na odcinku co najmniej 1 m z ka dej strony urz dzenia Przy monta u pionowym nale y zamontowa os on zewn trzn aby zabezpieczy urz dzenie przed wn...

Page 22: ...PL 22...

Page 23: ...PL 23 16 17 18...

Page 24: ...PL 24 19 20 21 22 23 24 25...

Page 25: ...PL 25 28 27 26...

Page 26: ...aj aby woda nie dosta a si do komponent w elektrycznych Wytrzyj powierzchnie do sucha TRANSPORT I PRZECHOWYWANIE Urz dzenie transportuj w oryginalnym opakowaniu Przechowuj urz dzenie w oryginalnym opa...

Page 27: ...ctional disorders or by persons who do not have sufficient experience or knowledge on how to use it unless they have received instructions concerning the use of the appliance from someone who is respo...

Page 28: ...to a 100 mm air duct The motor on the appliance has two speeds min and max The air flow in the system must correspond to the arrow on the fan casing A status light on the front panel shows the operati...

Page 29: ...horizontal installation the air ducts should have no bends for at least 1 metre on both sides of the appliance For vertical installation an external cover must be fitted to protect the appliance from...

Page 30: ...EN 30...

Page 31: ...EN 31 16 17 18...

Page 32: ...EN 32 19 20 21 22 23 24 25...

Page 33: ...EN 33 28 27 26...

Page 34: ...e with a cloth moistened with water and a mild detergent Make sure no water gets into the electrical components Wipe the surface dry TRANSPORT AND STORAGE Transport the appliance in the original pack...

Page 35: ...ad f r v rme tervinning N A Maximalt luftfl de 137 m h Ljudniv 56 dB A Maximal effekt 33 W Referensfl de 0 027 m s Referenstryckskillnad N A Specifik tillf rd effekt 0 219 W m h Typ av styrning Manuel...

Page 36: ...gjenvinning N A Maksimal luftstr m 137 m h Lydniv 56 dB A Maksimal effekt 33 W Referansestr m 0 027 m s Referansetrykkforskjell N A Spesifikk tilf rt effekt 0 219 W m h Type styring Manuell Maksimal i...

Page 37: ...w powietrza 137 m h Poziom ha asu 56 dB A Maksymalna moc 33 W Warto odniesienia nat enia przep ywu 0 027 m s Warto odniesienia r nicy ci nienia N A Energia wyj ciowa 0 219 W m h Rodzaj sterowania Manu...

Page 38: ...r recyling heat N A Maximum air flow 137 m h Noise level 56 dB A Maximum output 33 W Reference flow 0 027 m s Reference pressure difference N A Specific supplied output 0 219 W m h Type of control Man...

Reviews: