Ansell ASLED4 Installation Instructions Download Page 1

                                                                                        Description – IP65 Stormloc LED Non-Corrosive 

 

                       

®           

                

Installation Instructions          

 

                                                                                

                                                                                                  

Luminaire Code(s) -

 

ASLED

 

 

General Installation Instructions 
These instructions should be read carefully prior to any installation and retained after completion for further reference and maintenance. Please give 
these instructions to the building owner/occupier after installation. 

 

Important Safety 

1. 

Before installation, maintenance or lamp replacement, ensure that the mains supply to the luminaire is switched off and the circuit 
supply fuses are removed or the circuit breaker is turned off. 

2. 

It is recommended that only a qualified electrical contractor carries out the installation of this luminaire and that the luminaire is 
installed in compliance with the current edition of the IEE Wiring Regulations. 

3. 

The person carrying out the installation is to check and verify that the total load on the circuit, including that of this luminaire does 
not exceed the rating of the circuit cable, fuse or circuit breaker. 

4. 

Where a luminaire incorporates discharge control gear (inductive load), the circuit capacity and ratings require careful sizing to 
avoid nuisance tripping of the protective device used in the installation. 

5. 

Where applicable, careful consideration should be taken during installation to ensure that all fixings and/or suspensions are of a 
suitable size for the luminaire being installed. 

Ratings 

1.  All luminaires are manufactured & tested in compliance with the requirement contained within BS EN 60598 and are CE marked. 
3.  All luminaires that are of Class 1 construction and that are marked accordingly, MUST be earthed. 
3.  All luminaires are designed to operate at 230Volts AC -6%/+10% = 216Volts to 252Volts. Do not operate outside these voltages. 
4.  All luminaires are only suitable for applications within their rated Ingress Protection limits as stated. 

5. Max Ambient Temperature 25

o

 
Exclusions to Warranty 
Please Note - 

The limited warranty shall be null and void in the following circumstances:- 

 
Failure by the installer, end user or any third party to exercise caution to protect any covered product or part from outside damage, adverse temperature (normal operating 
ambient temperature 0 - 25°C), humidity conditions, fluctuations in the electrical system or physical abuse as well as failure related to workmanship in the installation of 
the products or parts.

 

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- 

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- 
Page No. 1                                                                     

www.anselluk.com

                                              Issue Date: td 20140512                                           

DO NOT DRILL THE BODY OF THIS LUMINAIRE FOR MOUNTING PURPOSES. THE LUMINAIRE IS ONLY DESIGNED FOR 

INSTALLATION, USING THE CLIPS AND HOOKS PROVIDED AND ONLY AT THE FIXING POINTS OF THE FITTING. ANY DRILLED 

HOLES DURING INSTALLATION WILL ALSO INVALIDATE THE IP RATING OF THE FITTING. 

 

Installation 
 

 

Determine the fixing centres from the sizes indicated on the box or from the table below. 

 

If mounting to ceilings, securely fix the stainless steel mounting clips using screw fixings provided at the spacing's mentioned above. For suspended mounting, use hanging 
hooks provided on the back of the fitting. 

 

Remove the front diffuser by unhinging stainless steel clips and gear tray assembly and place in a safe place until needed. 

 

Select a suitable cable entry point by drilling into the base at any of the 20mm entry points. (Suitable provision MUST be made to protect IP rating of luminaire).  

 

It is the installer’s responsibility to provide adequate electrical connections to maintain the correct IP rating for the installed environment. This is in accordance to BS EN 
7671. 

 

Use only circular HO7RN-F  cable, 0.75mm

2

 - 1mm

2

. Ensure the cable entry connector has a minimum water ingress rating of IPX5. 

 

Electrical Connections 

Connect as follows:-                           LIVE 

 

(L) 

BROWN OR RED 

(switched) 

    NEUTRAL 

(N) 

BLUE OR BLACK 

    EARTH   

                  GREEN / YELLOW 

 

 

Terminate the supply cable ensuring correct polarity is observed and the luminaire 

MUST

 be earthed. 

 

Replace the gear tray into the clips. 

 

Seat diffuser against gasket, fit clips into recess points in base and secure diffuser with clips. 

 

Lock the clips into the closed position by using the fixing screw supplied. 

 

Restore supply for satisfactory operation. 

 

Note :-    It is the responsibility of the installer/specifier to determine the suitability of this luminaire for the application. Luminaire types with high IP rating protection 

may not be suitable for installations with prolonged daily use due to accumulative heat not being able to dissipate from the luminaire body, affecting life 
span of components. 

 

   Product Code           Wattage /         
                                 Output Current 

Fixing Centres 

No. of Clips 

Spare Stainless Steel Clip 

Code 

ASLED4 

26W / 500mA 

907mm 

ADP/SS/CLIP 

ASLED5 

36W / 700mA 

907mm 

10 

ADP/SS/CLIP 

ASLED6 

42W / 1050mA 

1170mm 

12 

ADP/SS/CLIP 

ASLED2X4 

52W / 1050mA 

907mm 

ADP/SS/CLIP 

ASLED2X5 

72W / 700mA 

907mm 

10 

ADP/SS/CLIP 

ASLED2X6 

84W / 1050mA 

1170mm 

12 

ADP/SS/CLIP 

 
Operating Conditions 
 

LED Stormloc NCF 

This luminaire is designed to operate in a temperature range -20

o

C to +25

o

 
 

Reviews: