Display Setup Help
— Selecting this soft key displays a diagram of the rec-
ommended setup to use this option.
MEAS/DISP
If Option 5 (Power Monitor) is installed, it is possible to operate Option 5 and
Option 28 simultaneously. This could be practical for repeater measurements or
for high loss cable loss measurements. The following soft key is available by
pressing the
MEAS/DISP
function key while in CW Signal Generator mode:
q
Power Monitor External
— Displays the power from the external power mon-
itor.
SYS
In CW Signal Generator mode, pressing the
SYS
key displays the following
System menu soft key selection
q
System Options
— Displays a second level of system option functions:
q
Clock
— Displays a second level of functions:
q
Hour
— Enter the hour (0-23) using the Up/Down arrow key or the
keypad. Press
ENTER
when data entry is complete or
ESCAPE
to
restore the previous value.
q
Minute
— Enter the minute (0-59) using the Up/Down arrow key or
the keypad. Press
ENTER
when data entry is complete or
ESCAPE
to restore the previous value.
q
Month
— Enter the month (1-12) using the Up/Down arrow key or the
keypad. Press
ENTER
when data entry is complete or
ESCAPE
to
restore the previous value.
q
Day
— Enter the day using the Up/Down arrow key or the keypad.
Press
ENTER
when data entry is complete or
ESCAPE
to restore the
previous value.
q
Year
— Enter the year (2003-2036) using the Up/Down arrow key or
the keypad. Press
ENTER
when data entry is complete or
ESCAPE
to restore the previous value.
q
Back
— Returns to the top-level SYS menu.
q
Printer
— Displays a menu of supported printers. Use the Up/Down arrow
key and
ENTER
key to make the selection.
q
Units
— Select the unit of measurement (metric or English).
q
Change Date Format
— Toggles the date format between
MM/DD/YYYY, DD/MM/YYYY, and YYYY/MM/DD.
q
Back
— Returns to the top-level SYS menu.
q
Application Options
— Application options displays options applicable to par-
ticular mode.
q
External Ref Freq
— Set the external reference frequency from 2 MHz to
20 MHz.
q
Bias Tee
— Selects the Bias Tee.
q
Bias Tee Voltage
— Set the bias tee voltage between 12 and 24 Vdc,
in 1V increments, using the number keys or the Up/Down arrow keys.
q
Bias Tee On/Off
— Turn the bias voltage on or off.
q
Impedance
— Sets the input impedance of the instrument
Chapter 2 Functions and Operations
2-67
Summary of Contents for Cell Master MT8212B
Page 3: ......
Page 5: ......
Page 222: ...12 4 Chapter 12 GPS Feature Figure 12 3 Saved GPS Location Information...
Page 231: ...Chapter 13 CDMA Measurement 13 9 Figure 13 5 CDMA Display with Markers...
Page 255: ...Chapter 18 EVDO Mode 18 5...