ing the keypad or the Up/Down Arrow key (Figure
2-1, page 2-0). Press
ENTER
when the data entry is
complete.
Step 15.
Press the MAIN soft key to return to the Main Menu.
Adjusting a Limit
Step 16.
Press the
LIMIT
key (Figure 2-1, page 2-0) to call up
the Scale Menu.
Step 17.
If the Limit needs to be turned OFF, press the LIMIT
soft key on the Scale Menu. If the Limit needs to be
turned ON, press the LIMITsoft key again. This will
open the Limit parameter for entry. If needed, enter
the desired numerical value using the keypad or the
Up/Down Arrow key (Figure 2-1, page 2-0). Press
ENTER
when the data entry is complete.
Step 18.
If you wish to have an audible beep when the trace is
above the limit line, press the OPT soft key from the
Main Menu (page 2-8).
Step 19.
Press the B2 soft key from the Option Menu (page
2-19) to toggle the limit beep indicator
ON
.
Saving a Setup
Step 20.
Press the
SAVE SETUP
key (Figure 2-1, page 2-0).
Step 21.
Enter the desired numerical value using the keypad (1
to 9) or the Up/Down Arrow key. Press
ENTER
when data entry is complete.
2 - 30
Chapter 2 Operation
Summary of Contents for Site Master S330A
Page 3: ......
Page 15: ...This page is intentionally blank 1 7 Chapter 1 General Information...
Page 23: ...2 7 Chapter 2 Operation Figure 2 3 Site Master Menu Structure...
Page 54: ...2 38 Chapter 2 Operation Figure 2 10 Maximum Distance and Resolution vs Frequency Span...
Page 83: ...3 14 Chapter 3 Screen Capture Program NOTES...
Page 85: ...Color Cover P N 00986 00018...