Introduction

This manual provides description and maintenance instructions for models 36585K (70 kHz to 40 kHz) and 
36585V (70 kHz to 70 GHz) 2-Port AutoCal Calibration Kits. Part numbers and connector options are shown in 
the table below.
Use of the calibration kits and calibration procedures are documented in the VNA Operation Manual and 
Programming Guide.

1-2

Purpose 

The calibration kits contain all of the precision components and tools required to calibrate an Anritsu Vector 
Network Analyzer System for a 12-term error-corrected measurement.
AutoCal has been characterized by Anritsu and the characterization file is included for use by the host VNA. It 
is valid for 1 year from time of shipment. The characterization cycle for the 36585-Series AutoCal is 12 months 
assuming proper use and care of the module and its connectors.
AutoCal can be characterized using the MS4640x Series VNA, following the instructions in the VNA Operation 
Manual. However, Anritsu can only guarantee meeting its published specifications with Anritsu-characterized 
AutoCals.  

Table 1-1.

2-Port Precision AutoCal Models

Frequency Range

Connectors Type

Part Number

70 kHz to 40 GHz

K (male) to K (male)

36585K-2M

K (female) to K (female)

36585K-2F

K (male) to K (female)

36585K-2MF

70 kHz to 70 GHz

V (male) to V (male)

36585V-2M

V (female) to V (female)

36585V-2F

V (male) to V (female)

36585V-2MF

Summary of Contents for Precision AutoCal 36585 Series

Page 1: ...r 36585K Precision AutoCal 70 kHz to 40 GHz 2 port 36585V Precision AutoCal 70 kHz to 70 GHz 2 port Part Number 10410 00279 Revision C Published April 2015 Copyright 2015 Anritsu Company Anritsu Compa...

Page 2: ...LITY FOR CONSEQUENTIAL DAMAGES TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW IN NO EVENT SHALL ANRITSU COMPANY OR ITS SUPPLIERS BE LIABLE FOR ANY SPECIAL INCIDENTAL INDIRECT OR CONSEQUENTIAL DAMAG...

Page 3: ......

Page 4: ...h a degree that they cannot be unlawfully used for military purposes CE Conformity Marking Anritsu affixes the CE Conformity marking onto its conforming products in accordance with Council Directives...

Page 5: ...European Parliament and Council Directive 2002 96 EC Chinese RoHS Compliance Statement...

Page 6: ......

Page 7: ...nts 1 2 Chapter 2 Maintenance Instructions 2 1 Inspecting Connectors 2 1 2 2 Cleaning Connectors 2 1 2 3 Making the Connection 2 2 Torque Specifications and Tools 2 2 2 4 Measuring Pin Depth 2 3 Pin D...

Page 8: ...Contents 2 PN 10410 00279 Rev C 36585K 36585V RM...

Page 9: ...surement AutoCal has been characterized by Anritsu and the characterization file is included for use by the host VNA It is valid for 1 year from time of shipment The characterization cycle for the 365...

Page 10: ...ow Index Description 1 01 201 torque wrench 8 mm 0 9 N m 2 Characterization data on a USB memory device 3 36585 precision AutoCal 4 01 204 universal wrench for K and V connectors Additional included i...

Page 11: ...00279 Rev C 2 1 Chapter 2 Maintenance Instructions This chapter provides instructions on the care and use of precision connectors It includes information on inspection cleaning pin depth measurement...

Page 12: ...n dry compressed air 2 Apply a small amount of Isopropyl Alcohol IPA to a lint free cotton swab 3 Rotate the cotton swab around the connector avoiding lateral pressure 4 Blow out any remaining debris...

Page 13: ...nectors together Finger tighten the connection first by turning the connector nut Do not turn the connector body The final tightening is done using the appropriate torque wrench set to the correct tor...

Page 14: ...in depth is measured from a connector reference plane to a defined point on the connector center pin depending on the connector type A typical example of pin depth dimensions for a male and female con...

Page 15: ...uge coupling nut and adapters will vary depending on the connector type Checking the Gauge Pin depth gauges should be checked for cleanliness before each use Follow the connector cleaning procedure to...

Page 16: ...To measure V female connectors screw the male adapter onto the gauge coupling nut 6 Tolerance Gauge Settings Tolerance Gauge Settings Refer to Table 2 2 below When gaging pin depth if the test device...

Page 17: ...Maintenance Instructions 2 4 Measuring Pin Depth 36585K 36585V RM PN 10410 00279 Rev C 2 7...

Page 18: ...Anritsu utilizes recycled paper and environmentally conscious inks and toner Anritsu Company 490 Jarvis Drive Morgan Hill CA 95037 2809 USA http www anritsu com...

Reviews: