4.6 Jitter Tolerance Test
4-35
4
O
per
ation
Figure 4.6.2-3 PAM4 Threshold/Phase Settings Dialog Box
Table 4.6.2-3 PAM4 Threshold/Phase Settings Items
Item
Description
Manual Setting
Data Input Condition Displays the Input Condition settings of ED to be used for
measurement.
●
Single-End Data or XData
●
Differential 50Ohm
●
Differential 100Ohm
Threshold/Phase
Configure threshold and phase settings for Upper/Middle/Lower
eyes of PAM4 signal.
Pretest ON/OFF
When selecting the Pretest checkbox:
Verifies whether the measurement can be started using the
threshold and phase value specified by Auto Search or manually
before starting the AM4 Jitter Tolerance measurement.
If verified to be Sync Loss, you will be notified that measurement
does not start.
Figure 4.6.2-4 Definition of PAM4 Threshold Levels
Middle
Upper
Lower
Vtop_High
Vbottom_Low
Summary of Contents for MX183000A
Page 12: ...xii ...
Page 16: ...IV ...
Page 20: ...Chapter 1 Outline 1 4 Figure 1 1 3 Jitter Tolerance Graph Screen ...
Page 54: ...Chapter 3 Connecting Equipment 3 16 ...
Page 136: ...Chapter 5 Remote Control 5 30 Figure 5 8 2 Sequence Screen BER Measurement 10 8 9 11 ...
Page 206: ...Chapter 5 Remote Control 5 100 ...
Page 218: ...Appendix A Specifications A 12 ...