4.7 Jitter Tolerance Test Procedure
4-47
4
O
per
ation
Number
of retries
Ji
tte
r
am
pl
itud
e
1
2
3
4
5
6
Upper Value
Lower Value
:Measurement value
≤
Threshold
:Measurement value
>
Threshold
Step
Figure 4.7.1-2 Procedure for Downwards Linear measurement
Number of
retries
Ji
tte
r
amp
lit
ude
1
2
3
4
5
6
Upper
Value
Lower
Value
:Measurement value
≤
Threshold
:Measurement value
>
Threshold
A*Ratio
B*Ratio
A
A=Upper Value-Lower Value
B=A*Ratio
Figure 4.7.1-3 Procedure for Downwards Log measurement
●
Upwards
The jitter amplitude is increased from the Start Value until the error
measurement value exceeds the value of Threshold.
In the case of Upwards Linear, the jitter amplitude is increased by the
value set in Step.
In the case of Upwards Log, the jitter amplitude is increased by the
magnification set in Ratio.
In cases that the error measurement value still does not exceed the
Threshold even when the jitter amplitude becomes equal to or above
Upper Value, the next step jitter amplitude will be taken as the final
measurement value.
Number
of retries
Ji
tte
r
am
pl
itud
e
1
2
3
4
5
6
Upper Value
Lower Value
:Measurement value
≤
Threshold
:Measurement value
>
Threshold
Step
Figure 4.7.1-4 Procedure for Upwards Linear measurement
Summary of Contents for MX183000A
Page 12: ...xii ...
Page 16: ...IV ...
Page 20: ...Chapter 1 Outline 1 4 Figure 1 1 3 Jitter Tolerance Graph Screen ...
Page 54: ...Chapter 3 Connecting Equipment 3 16 ...
Page 136: ...Chapter 5 Remote Control 5 30 Figure 5 8 2 Sequence Screen BER Measurement 10 8 9 11 ...
Page 206: ...Chapter 5 Remote Control 5 100 ...
Page 218: ...Appendix A Specifications A 12 ...
Page 226: ...Appendix B Default Settings B 8 ...