4.13 Time Domain Graph Display
4-197
4.13.13 Displaying the Time Domain screen from the Convert screen
By displaying the Time Domain screen from the Convert screen, the
pre-conversion waveform pattern can be checked and the range for RMS
calculation during conversion can be specified.
However, when the Time Domain screen is displayed from the Convert
screen, traces cannot be added or deleted.
On the Time Domain screen, to specify the RMS-calculation range used
for waveform conversion on the Convert screen, use the black-line and
yellow-line cursors.
Calculate the RMS using this
range.
Figure 4.13.13-1 RMS Value Calculation Range
After specifying the RMS-calculation range by using the black-line and
yellow-line cursors, click the Set RMS Range button to specify the
RMS-calculation range used when converting the waveform pattern on
the Convert screen and close the Time Domain screen.
Figure 4.13.13-2 Set RMS Range Button