Level Offset
Level offset lets you compensate for a device on the
signal generator's output that alters the RF output
power level at the point of interest. For example, the
power level at the test device may be less or more
than the displayed power level because of the loss
through an external transmission line or the gain of
an amplifier located between the MG369XB RF out-
put and the test device. Using the level offset func-
tion, you can apply a constant to the displayed
power level that compensates for this loss or gain.
The displayed power level will then reflect the ac-
tual power level at the test device.
To enter an offset value and apply it to the displayed
power level, access the Level menu. Then press
Edit Offset [LOS]
. This opens the offset parameter
for editing (below).
Edit the current offset value using the cursor con-
trol keys, rotary data knob, or enter a new offset
value using the keypad and appropriate termination
soft-key. To close the open offset parameter when
you are done, press
Edit Offset
or make another
menu selection.
3-54
MG369XB OM
Fixed Power Level Operation
Local (Front Panel) Operation