XL9 <value> <unit>
Description:
Opens the L9 parameter.
Permits setting the L9 parameter. The power level setting is determined by the power
level range of the particular MG369xC model.
Functional
Category:
PARAMETER ENTRY
Value:
Power level range of the MG369xC model
Units:
DM (log), VT (linear)
Output Command:
OL9
returns the L9 power level (in dBm when in log mode; in mV when in linear mode)
to the controller.
Related
Commands:
LOG
,
LIN
,
PU0
,
PU1
,
PU2
Front Panel Key:
Level
|
Level
|
Level Control >
| highlight
L9
, then press
Edit Selected
XP
Description:
Turns on the external pulse modulation function. Disables the internal pulse modulation
function, if previously programmed.
Turns on the pulse modulation function. If pulse modulation is not installed, this
command produces a syntax error.
Functional
Category:
MODULATION
Related
Commands:
EP0
,
EP1
,
PO
Front Panel Key:
Modulation
| Pulse | On/Off to On
Y
Description:
Sending a Y is equivalent to sending a Group Execute Trigger (GET).
Functional
Category:
GROUP EXECUTE TRIGGER
Front Panel Key:
N/A
ZEL
Description:
Ends frequency loading.
In the fast-frequency-switching mode, up to 1000 frequencies can be loaded into a table
using this command. A table pointer can then be set to point to a specific frequency in the
table and the MG369xC commanded to switch from that frequency through the following
frequencies to the bottom of the table.
Functional
Category:
FAST-FREQUENCY-SWITCHING
Front Panel Key:
N/A