Page 1: ...INSTRUCTION MANUAL HANDHELD THERMOMETER HD 1500 Series 4th edition Jul 2018 AE 100236 ANRITSU METER CO LTD 2 4 5 Shimomeguro Meguro ku Tokyo 153 0064 Japan Tel 81 3 3491 9181 Fax 81 3 3493 6792...
Page 2: ......
Page 3: ...hargeable model Please observe the following matters to guard the battery leakage exothermic reaction and ignition Do not throw away the battery cells in the fire and avoid short between electrodes Do...
Page 4: ......
Page 5: ...y make this manual however if there are any error or not clear please contact the place of purchase or us We are not responsible for the consequences of using this product After sales Service ANRITSU...
Page 6: ...ON OFF 6 5 2 Hold 6 5 3 Automatic Power OFF 7 5 4 Resolution change 7 5 5 P V Hold 8 5 6 Backlight 8 6 Setting the clock 9 7 Memory Function 10 7 1 Setting Interval 10 7 2 Starting Memory Measurement...
Page 7: ...ndicator of Battery remain 32 12 Error Messages 33 12 1 Main Unit Error Messages 33 12 2 Software Error Messages 34 13 Uninstall 36 14 Maintenance 36 14 1 Storage 36 14 2 Case cleaning 36 15 In case o...
Page 8: ...he batteries of the main unit run out 2 Unpacking 2 1 Unpacking Open the carton and the check that the following are provided If any of them is missing or out of order please contact the place of purc...
Page 9: ...2 3 Name of Components 3 1 Name of Components MODEL HD 1500 Sensor Input connector USB connector LCD Display Key switch panel AC adaptor jack Battery housing Hand strap...
Page 10: ...3 3 2 Display of all segments Hold Auto power off Battery Indicator P V hold Main Display Peak Memory Sub display1 Interval Valley Sub display2...
Page 11: ...bject 4 2 How to Use Hand Strap Hang the hand strap around the hand to prevent in advertent drop of the instrument Thread the fine cord end of the hand strap through the strap attachment on the instru...
Page 12: ...nsor as shown The plug is so designed that it will not be set when the polarity is reversed Forcible insertion will damage the instrument Be sure to check the polarity HD 1500 HD 1550 4 5 Soft case Us...
Page 13: ...the key again to turn power OFF 5 2 Hold Press the HOLD key to stop measurement and show the measured Temperature on the display Then HOLD appears on the display Press the key again to return to the n...
Page 14: ...yed temperature 0 1 resolution Range is from 104 9 504 9 at every 0 1 When the measured value exceed this range the resolution changes to 1 automatically 1 resolution All measurable range at every 1 R...
Page 15: ...le when the memory function is activated The P V HOLD mode cannot be set when Burnout or Over range display appears Normal measurement P V Hold mode 5 6 Backlight Press the key to turn the backlight O...
Page 16: ...select the digits to set Use the SET key to increment the set values Press the SET key with the minutes setting selected to set the seconds readout to 00 and exit clock setup The instrument uses a lit...
Page 17: ...Up to 9999 data items can be stored in memory The remaining memory capacity is displayed in the bottom right sub display area when the interval is set The SET key operation is disabled once the remain...
Page 18: ...w transfer of memory data to a PC as a single data block Up to 2 000 data blocks can be handled During memory measurement the sub display in the bottom left area changes as follows each time the SET k...
Page 19: ...If the memory contains only one block the block number remainsunchangedwhenthe keyor keyispressed Up to 2 000 data blocks can be stored in memory When a block number is set for display the letters ME...
Page 20: ...ss the POWER key while holding down the SET key This powers on the instrument The memory clear display appears To clear the data press the SET key To cancel without clearing the data press the STOP ke...
Page 21: ...15 0 to a PC you must install the application software found on the CD ROM provided with the product OS Microsoft Windows 7 Microsoft Windows 8 1 Microsoft Windows 10 Requires a PC of specifications s...
Page 22: ...other software application is running Insert theAMS 100 CD ROM in the CD ROM or DVD RW drive Run SETUP exe when the AutoPlay window opens If the AutoPlay window does not open automatically double clic...
Page 23: ...r in the following status Computer without the system administrator privileges Computer set to restrict a third party USB driver to install other USB drivers In this case please use a different comput...
Page 24: ...17 4 Right click Computer inthe Startmenu Selectthe Manage 5 Clickthe DeviceManager MakesurethatyouhaveUSBTESTinthe Otherdevices...
Page 25: ...18 6 Right clickUSBTESTandselect Properties Then click UpdateDriver Samescreenopenswhendouble clickingUSBTEST...
Page 26: ...19 7 Click Browsemycomputerfordriversoftware 8 Insert the CD into your PC Click Browse select the CD from lists and click Next...
Page 27: ...20 Click Install...
Page 28: ...21 9 Whentheinstallationiscompleted theAddHardwarewizardshownbelowwillbe displayed ClickFinish 10 Check to see that DCUSB is found below the heading Universal Serial Bus controllers...
Page 29: ...1 Connect the measuring instrument and computer with the USB communication cable 2 Turnonthepowertothemeasuringinstrument 3 Click PCsettings inthe Startmenu 4 Click ControlPanel inthemenu 5 Click Har...
Page 30: ...23 6 Clickthe DeviceManager MakesurethatyouhaveUSBTESTinthe Otherdevices...
Page 31: ...24 7 Right clickUSBTESTandselect Properties Then click UpdateDriver Followtheinstructionsfrom 6 onWindows7theinstallation Selectthe Devicesmanager intheSystemproperties...
Page 32: ...25 Windows 10 1 Connect the measuring instrument and computer with the USB communication cable 2 Turnonthepowertothemeasuringinstrument 3 Click Settings inthe Startmenu 4 Click Devices...
Page 33: ...26 5 Click Devicemanager inthePrinters scanners MakesurethatyouhaveUSBTESTinthe Otherdevices...
Page 34: ...27 6 Right clickUSBTESTandselect Properties Then click UpdateDriver Followtheinstructionsfrom 6 onWindows7theinstallation Selectthe Devicesmanager intheSystemproperties...
Page 35: ...ending on the amount of data involved 9 4 Transferring Data Connect the measuring instrument and computer with the USB communication cable and turn on the power to the measuring instrument Select the...
Page 36: ...is retained even after you selected to run Data Input if a communication error etc occurs during communication reselect Data Input The transferred data is saved as a CSV format file in the HD DATA fol...
Page 37: ...opened and edited in spreadsheet software If you are using Microsoft Excel the file will be displayed in a manner similar to the samples shown below You can create a graph the file by making use of t...
Page 38: ...31 Time display Absolute time Displayed in graph form using the Microsoft Excel graph function In manual measurement the time when data measurement was performed is displayed...
Page 39: ...and an abnormal time readout error will occur If this happens the lithium battery must be replaced by the place of purchase or byAnritsu Meter Afee will be charged for this replacement 11 Indicator o...
Page 40: ...ars shown as left Check whether the sensor burns out or does not connect to instrument 2 Indication of Over range If the temperature exceeds the measurable range during measuring the Over range displa...
Page 41: ...nes When the remaining battery is almost empty a warning alarm sounds and the battery display appears The battery will turn off immediately 12 2 Software Error Messages This section describes the most...
Page 42: ...35 2 If the measuring instrument cannot be communicated with 3 If the file name exceeds 9999 4 If data is not saved in the measuring instrument...
Page 43: ...Programs and Functions 2 SelectAMS 100 and click Uninstall 14 Maintenance 14 1 Storage Avoid places subject to the following when storing the instruments Direct Sunlight Strong vibration High humidity...
Page 44: ...he plug of the sensor with the instrument again If the senor does not hold in the correct position measurement value does not stable If you measure in the environment of strong electromagnetic field a...
Page 45: ...ttery Lithium Battery Backup for clock Battery Life Approx 5 years store at room temperature Environmental limit Operation 0 40 0 80 RH Storage 20 50 0 85 RH Dimensions 76 W 167 H 36 D mm Weight Appro...
Page 46: ...w 0 0 5 Accuracy Cold junction compensation 0 2 at 25 10 Temperature coefficient 0 01 of F S Except 25 10 Input Type K Resolution 1 0 1 Measurement range 200 1370 100 0 500 0 Accuracy 0 or more 0 1 of...