LTE Signal Analyzer
5-11 Setup Menu
3GPP MG
PN: 10580-00234 Rev. V
5-31
5-11 Setup Menu
Key Sequence:
Setup
BW:
Opens the Select Bandwidth list. Choose from the available
bandwidths.
Cyclic Prefix:
Press this key to set the instrument to measure signal with
a Normal or Extended Cyclic Prefix, or to allow the instrument to detect
the Cyclic Prefix automatically.
EVM Max Hold:
Turn the EVM Max Hold submenu key On to display both
the Maximum EVM value since Reset and the current measured value.
This applies to EVM RMS and Peak values. Selecting Off displays only
the current measured value.
EVM Mode:
Press to select either Auto or PBCH Only. Selecting Auto
measures PDSCH if data is available, otherwise, it measures PBCH.
Selecting PBCH Only forces a PBCH measurement and the constellation
measurement will only show QPSK. The instrument will automatically
choose PBCH Only mode when the OTA Scanner is used.
Sync:
Opens the Sync submenu.
Sync Type:
Press to choose between the Normal (SS) or RS
(Reference Signal) Sync Type. Only choose RS when there is no
sync signal present in the transmitter under test. If RS is chosen
and a sync signal is present, no modulation measurements will be
available.
Cell ID:
Identifying information sent by the transmitter in the sync
signal. If Normal (SS) is selected as the Sync Type, the Cell ID is
extracted automatically from the Sync Signal. The Cell ID must be
entered manually when RS Sync Type is selected. For user
convenience, the Cell ID is automatically populated from the last
measured signal with an SS.
Select noSS Antenna:
Selects which antenna in a 4x4 MIMO
system that does not receive a sync signal. Antenna 0 must receive
a sync signal.
Back:
Returns to the Setup menu.
Freq Err Avg Cnt:
When the count is greater than one, the frequency
error value is averaged over past measurements. If the count is one, then
no averaging occurs.
Ext. Ref. Freq (Only Some Models):
Press to set the external reference
frequency. The External Reference Frequency list opens. Highlight the
desired frequency and press
Enter
.
Figure 5-24.
LTE Setup Menu
Back
Sync
Sync Type
Normal (SS) RS
Cell ID
0
Select noSS Antenna
1
EVM Max Hold
Off On
Setup
BW
10 MHz
EVM Mode
Auto PBCH Only
Freq Err Avg Cnt
1
Sync
Ext. Ref. Freq
Cyclic Prefix
Auto Norm Extd
Summary of Contents for BTS Master MT8221B
Page 1: ...BTS Master User Guide MT8221B and MT8222B The High Performance Handheld Base Station Analyzer ...
Page 2: ......
Page 4: ......
Page 6: ......
Page 8: ......
Page 24: ...1 12 Secure Environment Workplace General Information 1 10 PN 10580 00207 Rev E BTS Master UG ...
Page 46: ...2 13 Firmware Overview Instrument Overview 2 22 PN 10580 00207 Rev E BTS Master UG ...
Page 54: ...3 8 PN 10580 00207 Rev E BTS Master UG ...
Page 88: ...7 8 PN 10580 00207 Rev E BTS Master UG ...
Page 94: ...8 5 Updating Instrument Firmware Master Software Tools 8 6 PN 10580 00207 Rev E BTS Master UG ...
Page 95: ...Master Software Tools 8 5 Updating Instrument Firmware BTS Master UG PN 10580 00207 Rev E 8 7 ...
Page 96: ...8 5 Updating Instrument Firmware Master Software Tools 8 8 PN 10580 00207 Rev E BTS Master UG ...
Page 97: ...Master Software Tools 8 5 Updating Instrument Firmware BTS Master UG PN 10580 00207 Rev E 8 9 ...
Page 114: ...C 8 PN 10580 00207 Rev E BTS Master UG ...
Page 118: ...Index 4 PN 10580 00207 Rev E BTS Master UG ...
Page 152: ...2 18 Other Menus GSM GPRS EDGE Signal Analyzer 2 18 PN 10580 00234 Rev V 3GPP MG ...
Page 196: ...3 18 Other Menus W CDMA HSPA Signal Analyzer 3 44 PN 10580 00234 Rev V 3GPP MG ...
Page 224: ...4 16 Other Menus TD SCDMA HSPA Signal Analyzer 4 28 PN 10580 00234 Rev V 3GPP MG ...
Page 272: ...5 19 Other Menus LTE Signal Analyzer 5 48 PN 10580 00234 Rev V 3GPP MG ...
Page 338: ...7 5 Coverage Mapping Menu LTE and TD LTE Coverage Mapping 7 16 PN 10580 00234 Rev V 3GPP MG ...
Page 354: ...8 4 W CDMA EMF Menu EMF Option 444 8 16 PN 10580 00234 Rev V 3GPP MG ...
Page 360: ...Index 4 PN 10580 00234 Rev V 3GPP MG ...
Page 361: ......