4.6 Linking Measurement Settings for Multiple Channels
4-17
4
Screen Oper
ation
4.6 Linking Measurement Settings for Multiple
Channels
Ch Tracking is displayed for the Options 012 or 014.
Touching [on] sets the PPG and ED settings for Ch1 to the PPG and ED
settings for other channels. In this state, altering settings for Ch1 also
alters the settings for other channels.
Figure 4.6-1 Ch Tracking
The following settings are linked:
Programmable Pattern
Data Length
ED Tracking*
ED Gating Cycle (Repeat/Single/Untimed)
ED Gating Period
*: Setting Ch Tracking to On sets ED Tracking to On. However, setting
Ch Tracking to Off does not set ED Tracking to Off.
Setting Ch Tracking to On sets the Ch2 Reference CLK to [Ch1].
Summary of Contents for BERTWave MP2100B
Page 24: ...xxiv...
Page 96: ...Chapter 2 Before Use 2 42...
Page 112: ...Chapter 3 Connecting with DUT 3 16...
Page 250: ...Chapter 7 Measuring Waveform 7 64 Figure 7 12 1 Marker Display...
Page 262: ...Chapter 7 Measuring Waveform 7 76...
Page 276: ...Chapter 8 Operating Optical Interface 8 14...
Page 304: ...Chapter 9 Performance Test 9 28...
Page 320: ...Chapter 10 Maintenance 10 16...
Page 374: ...Appendix E Performance Test Record Form E 10...
Page 382: ...Index Index 6...