Chapter 3 Connecting with DUT
3-14
3.4 Measuring QSFP Module Bit Error Rate
The QSFP module contains four pairs of transmitters and receivers. With
the Option 014, the QSFP Module bit error rate can be measured for four
channels simultaneously.
If using a separate QSFP for transmission in addition to the DUT QSFP,
connect as follows. Use coaxial cables of the same length as for between
Data Out and
Data
Out to connect the BERTWave and QSFP. Bit error
rate cannot be measured correctly if different length coaxial cables are
used.
1. Connect the PPG1-PPG4 Data Out and Input connector on the
transmission QSFP using a coaxial cable.
2. Connect
the
PPG1-PPG4
Data
Out and Input connector on the
transmission QSFP using a coaxial cable.
3. Connect the DUT QSFP output connector and ED1-ED4 Data In
using a coaxial cable.
4. Connect the DUT QSFP output connector and ED1-ED4
Data
In
using a coaxial cable.
5. Connect the optical output connector of the transmission QSFP to
the input connector of the optical attenuator using an optical fiber.
6. Connect the output connector of the optical attenuator to the optical
coupler.
7. Connect one end of the optical coupler to the input connector of the
DUT QSFP.
8. Connect the other end of the optical coupler to the optical power
meter.
An optical switch can be used in place of the optical coupler.
Summary of Contents for BERTWave MP2100B
Page 24: ...xxiv...
Page 96: ...Chapter 2 Before Use 2 42...
Page 112: ...Chapter 3 Connecting with DUT 3 16...
Page 250: ...Chapter 7 Measuring Waveform 7 64 Figure 7 12 1 Marker Display...
Page 262: ...Chapter 7 Measuring Waveform 7 76...
Page 276: ...Chapter 8 Operating Optical Interface 8 14...
Page 304: ...Chapter 9 Performance Test 9 28...
Page 320: ...Chapter 10 Maintenance 10 16...
Page 374: ...Appendix E Performance Test Record Form E 10...
Page 382: ...Index Index 6...