background image

1

User instructions

ArcLine 6 

The module generate colored light by means of Luxeon LEDs.The product was designed to use with the

ArcPower drivers and for indoor use only.

1.Attention

  

Do not install the module near high inflammable liquids or materials

 

 

Do not allow anything to rest on the module

 

 

Do not use the module near high humidity or water or expose to the rain

 

 

Do not install the module near the naked flames

 

 

Do not install the module in dirty,dusty or badly ventilated location

 

2.Installation

The ArcLine unit should be connected to the ArcPower driver according to the LED colour 

variants (RGB,WW,CW...).

See the ArcPower 36/72/144/360/384 R.M./16x6/16x12 (or their smartwhite variants) user manuals for full 

details of mains power requirements and DMX operation.

 

ArcLine units are supplied with 1.5 m of cable for direct connection to the ArcPower drivers.

CAUTION!

Avoid looking  directly into the LED light beam at close range!

Maximum possible number of LED modules connected to the one ArcPower 36 (or one LED output of the 

ArcPower 72/144/360) is mentioned in the table below.

Module 

(colour variant)

Total

LEDs

Red

LEDs

Green

LEDs

Blue

LEDs

Amber

LEDs

Cool

white

LEDs

Warm

white

LEDs

Max.number 

of connected 

modules 

Compatible power

supplies

ArcLine 6 RGB

6

2

2

2

-

-

-

6

ArcPower 36/72/144/360/

/384 R.M./16x6/16x12

ArcLine 6 CW

6

-

-

-

-

6

-

6

ArcPower SmartWhite 36/72

ArcPower SmartWhite 144/360

ArcLine 6 WW

6

-

-

-

-

6

6

ArcPower SmartWhite 36/72

ArcPower SmartWhite 144/360