background image

MODE

POWER

OUT

H3C-R

0

30

5

25

10

20

sec

A

15

ANLY

3

2

1

8

9

10

11

7

6

5

4

SOURCE

START

GATE

RESET

4

3

2

1

8

7

6

5

SOURCE

A

Set time = t , t - a < t , Reset time = Rt

SOURCE (2-7)

N.C. (8-5)
N.O. (8-6)

N.C. (1-4)

N.O. (1-3)

OUTPUT LED

POWER LED

t

t

t - a

Rt

Rt

Set time = t , t - a < t , Reset time = Rt

SOURCE (2-7)

N.C. (8-5)
N.O. (8-6)

N.C. (1-4)

N.O. (1-3)

OUTPUT LED

POWER LED

t

t

t

t

t

t - a Rt

Set time = t , t - a < t , Reset time = Rt

0.5s

0.5s

SOURCE (2-7)

N.C. (8-5)
N.O. (8-6)

N.C. (1-4)

N.O. (1-3)

OUTPUT LED

POWER LED

t

t

Rt

Rt t - a

Set time = t , t - a < t , Reset time = Rt

Rt

t

0.6s

0.6s

0.6s

t

t

t

0.6s

t - a

SOURCE (2-7)

N.C. (8-5)
N.O. (8-6)

N.C. (1-4)

N.O. (1-3)

OUTPUT LED

POWER LED

Set time = t , t - a < t , Reset time = Rt

SOURCE (2-7)

N.C. (1-4, 8-5)
N.O. (1-3, 8-6)

OUTPUT LED

POWER LED

t

t

t

t

t

t - a Rt

Set time = t , t - a < t , Reset time = Rt

SOURCE (2-7)

N.C. (1-4, 8-5)
N.O. (1-3, 8-6)

OUTPUT LED

POWER LED

t

t

t - a

Rt

Rt

Set time = t , t - a < t , Reset time = Rt

SOURCE (2-7)

N.C. (8-5)
N.O. (8-6)

N.C. (1-4)

N.O. (1-3)

OUTPUT LED

POWER LED

t

t

t - a

Rt

Rt

Set time = t , t - a < t , Reset time = Rt

SOURCE (2-7)

N.C. (1-4, 8-5)
N.O. (1-3, 8-6)

OUTPUT LED

POWER LED

t

t

t - a

Rt

Rt

P r o d u c t   i s   s u b j e c t   t o   c h a n g e   w i t h o u t   n o t i c e .

A

 : 

ON delay (2C)

A

4 : 

ON delay (1A1C)

C

 : 

Interval (2C)

B

3 : 

Repeat cycle ON start (1A1C)

E

 : 

Interval (1A1C)

J

 : 

One shot output (1A1C)

B

 : 

Repeat cycle OFF start (2C)

B

4 : 

Repeat one shot output (1A1C)

CONNECTION

BASIC SETTING

Mode Window

Groove for

screwdriver

Mode Selector

Scale Selector

Setting Operation Mode

Turn the Mode Selector with a screwdriver in either 
clockwise or counter-clockwise direction until the 
desired operation mode (A, A

4

, B, B

3

, B

4

, C, E, or J) is visible through the Mode Window. Make sure 

the selector snaps into a secured position, not between two modes.

Setting Time Scale

Turn the Scale Selector with a screwdriver and the time scale will cycle through all values. 
Stop when the desired scale range (1.2, 3, 12, 30) and the scale unit (sec, min, hrs, 10h) are visible 
through the Scale Range Windows and the Scale Unit Window respectively. 
Clockwise turns increment the time scale; counter-clockwise turns decrement the scale. 
Make sure the selector snaps into a secured position, not between two scales.

Operating  voltage

Allowable  operating
voltage  range

Rated  frequency

Contact  rating

Reset time

Power  consumption

Life

Ambient  temperature

Ambient  humidity

Weight

Mechanical : 5,000,000 times  /  Electrical : 100,000 times

85 ~ 110% of  rated  operating  voltage

50 / 60Hz

MAX 0.1s

250VAC 5A (Resistive  load)

Approx.  3VA

-10

+50 

o

C

MAX 85% RH

Approx.  100g

AC/DC : 24

240V

NAMES AND FUNCTIONS OF FACEPLATE

SPECIFICATIONS

Mode Selector

Mode Window

Scale Selector

Scale Range Windows

Scale Unit Window

LEDs

Time Dial

POWER: Power indicator(Flashes
when Timer operates; lit when 
Timer stops operating)

OUT: Output indicator(Lit when 
output is ON)

This manual uses the following symbols to ensure safe operation of this timer.

to user.

MULTI-FUNCTION 

ANALOGUE TIMER

User's Manual

SAFETY  PRECAUTION

WARNING

CAUTION

Warnings are indicated when mishandling this product might result in death or serious injury 

Cautions are indicated when mishandling this product might result in minor injury to the user, 

or only physical damage to the timer.

Note this incorrect wiring of this product can damage it and lead to other hazards. Make sure the product has 

    been correctly wired before turning the power ON.

Before wiring, or removing / mounting the product, be sure to turn the power OFF. Failure to do so might cause 

    electric shock.

Do not touch electrically charged parts such as the power terminals. Doing so might cause electric shock.

Do not disassemble the product. Doing so might cause electric shock or faulty operation.

Use the product within the operating ranges recommended in the specification (temperature, humidity, voltage, 

    shock, mounting direction, atmosphere etc.). Failure to do so might cause fire or faulty operation.

Firmly tighten the wires to the socket. Insufficient tightening of the wires to the socket might cause fire.

WARNING

CAUTION

RESTRICTIONS ON USE

When using this product in applications 
that require particular safety or when 
using this product in important facilities, 
please pay attention to the safety of the 
overall system and equipment. Install fail-
safe mechanisms, perform redundancy 
checks and periodic inspections and 
adopt other appropriate safety measures 
when it is necessary. This product is rated 
at Class 

Ⅱ     

.

Meraserw-5 s.c. 70-312 Szczecin , ul.Gen.J.Bema 5 , tel.(91)484-21-55 , fax (91)484-09-86 , e-mail: [email protected] , www.meraserw.szczecin.pl

H3C-R

8  /  H3C-R11

                H3C-

R8

H3C-R11

TIMING CHART(Output mode) for H3C-R

8

Summary of Contents for H3C-R8

Page 1: ...t rating Reset time Power consumption Life Ambient temperature Ambient humidity Weight Mechanical 5 000 000 times Electrical 100 000 times 85 110 of rated operating voltage 50 60Hz MAX 0 1s 250VAC 5A Resistive load Approx 3VA 10 50 o C MAX 85 RH Approx 100g AC DC 24 240V NAMES AND FUNCTIONS OF FACEPLATE SPECIFICATIONS Mode Selector Mode Window Scale Selector Scale Range Windows Scale Unit Window L...

Page 2: ... t t t a t a t a SOURCE 2 10 START 2 6 RESET 2 7 N C 1 4 11 8 N O 1 3 11 9 OUTPUT LED POWER LED Set time t t a t t t t t t a t a SOURCE 2 10 START 2 6 RESET 2 7 N C 1 4 N O 1 3 N C 11 8 N O 11 9 OUTPUT LED POWER LED Set time t t a t t t t t t t a SOURCE 2 10 START 2 6 RESET 2 7 N C 1 4 N O 1 3 N C 11 8 N O 11 9 OUTPUT LED POWER LED SOURCE 2 10 START 2 6 GATE 2 5 RESET 2 7 N O 11 9 N C 11 8 OUTPUT ...

Page 3: ...uency Reset time Contact rating Power consumption Life Ambient temperature Ambient humidity Mechanical 5 000 000 times Electrical 100 000 times 85 110 of rated operating voltage AC DC V 24 240 50 60 Hz MAX 0 1s 250VAC 5A resistive load Approx 3VA 10 50 C MAX 85 RH Weight Approx 100g Output contact Type E x tern al Rese t E x ternal S t art E xt er n al G at e 1 2s 3s 12s 30s 1 2m 3m 12m 30m 1 2h 3...

Page 4: ...ime t t a t Reset time Rt Set time t t a t Reset time Rt Set time t t a t Reset time Rt Set time t t a t Reset time Rt t t t t t t a SOURCE 2 10 Start signal 2 6 Reset 2 7 N C 1 4 N O 1 3 N C 11 8 N O 11 9 Output LED Power LED SOURCE 2 7 N C 8 5 N O 8 6 N C 1 4 N O 1 3 Output LED Power LED t t t t t t a Rt t t t t t t a SOURCE 2 10 Start signal 2 6 Reset 2 7 N C 1 4 11 8 N O 1 3 11 9 Output LED Po...

Page 5: ...ime t t a t Reset time Rt Set time t t a t Reset time Rt Set time t t a t Reset time Rt Set time t t a t Reset time Rt t1 t2 SOURCE 2 7 N C 8 5 N O 8 6 N C 1 4 N O 1 3 Output LED Power LED t t t a Rt Rt t 0 5s t t a t a SOURCE 2 10 Start signal 2 6 Reset 2 7 N C 1 4 N O 1 3 0 5s 0 5s 0 5s N C 11 8 N O 11 9 Output LED Power LED SOURCE 2 7 N C 8 5 N O 8 6 N C 1 4 N O 1 3 Output LED Power LED t t Rt ...

Page 6: ...EL 60 3 7983 5758 FAX 60 3 7981 5052 MALAYSIA BRANCH JUSTY ELECTRONICS M SDN BHD Flat K 13 F Edward Mansion 141 Prince Edward Road W Kowloon Hong Kong TEL 852 2397 2505 FAX 852 2397 6080 HONG KONG BRANCH ANLY ELECTRONICS HK LTD Room 3D Zhaofeng Building No 9 Alley 396 Changning Rd Changning District Shanghai China 200042 TEL 86 21 6213 9371 FAX 86 21 6212 3483 CHINA SALES OFFICE ANLY TECHNOLOGY WU...

Reviews: