background image

28-VSP-FSP-00 Rev A 

 

 

 

 

 

 

PERISTALTIC METERING PUMPS 

 

 

 

 

 

 

 

MODELS: VSP & FSP  

OPERATING MANUAL 

 
 
 

® 

Summary of Contents for FSP

Page 1: ...28 VSP FSP 00 Rev A PERISTALTIC METERING PUMPS MODELS VSP FSP OPERATING MANUAL ...

Page 2: ...N 3 4 0 OPERATION 4 4 1 Controls 4 4 2 Adjusting Flow Output 4 4 3 Remote Operation 4 5 0 MAINTENANCE 5 5 1 Routine Inspection 5 5 2 Tube Replacement 5 5 3 Pumphead Maintenance 6 5 4 Fuse Replacement 6 6 0 TROUBLESHOOTING 7 7 0 REPLACEMENT PARTS 7 8 0 LIMITED WARRANTY 8 9 0 RETURNS REPAIRS 8 ...

Page 3: ...er to the pump prior to conducting and maintenance or repairs WARNING Risk of chemical exposure Always wear protective clothing including gloves and safety eye protection when working on or near this pump WARNING Risk of chemical exposure Always depressurize system and drain chemicals prior to installation or maintenance WARNING Risk of fire or explosion Do not pump flammable liquids WARNING Risk ...

Page 4: ...he pump lower than the solution tank will gravity feed the solution and create a flooded suction installation In this scenario a shut off valve or other device must be installed to stop the solution flow to the pump during pump servicing In installations involving pressure a check valve should be used at the point of injection to prevent potential backflow DO NOT mount pump directly over an open s...

Page 5: ...otentiometer Rates are adjustable from approximately 5 to 100 If equipped with a 4 20mA control option pump speed will vary as the dedicated input signal changes amplitude Please refer to Remote Operation below for more details on 4 20mA operation Cycle Timer Models Cycle time is defined as the sum of the on time plus off time On time is set by the position of the potentiometer and can be incremen...

Page 6: ...cing the Tubing Pump tubing must be replaced on a regular basis While replacement within 500 hours of run time is recommended tube longevity is ultimately determined by many factors including tube formulation the chemical composition of the fluid being pumped system back pressure pump speed temperature and more Use only factory designated tubing Incorrect tubing can adversely affect performance or...

Page 7: ... pumphead to prevent tube migration during operation Figure 5 5 3 Pumphead Maintenance 1 Remove tubing per the Tubing Removal procedure 2 Disconnect power to the pump 3 Remove the pumphead cover 4 Open the spring clip to release the rotor from the motor shaft Figure 6 5 Remove roller assembly by sliding it off the motor shaft Once disassembled remove any particles or debris from the pumphead housi...

Page 8: ...own fuse Replace Fuse Outlet is not powered Verify that the unit is plugged into functioning outlet IEC plug has a loose connection Verify the power cord is firmly attached to IEC receptacle Gearbox assembly is worn Replace unit Unit is ON but pump will not turn Non compatible tubing used Use specified tubing Gearbox assembly worn Replace unit Pump runs but does not meet rated flow Tubing is worn ...

Page 9: ...any costs of removal installation transportation or other charges which may arise in connection with a warranty claim ANKO makes no warranties either express or implied other than those stated above No representative has authority to change or modify this warranty in any respect Jurisdiction and venue for enforcement of this warranty may be brought only in the State of Florida This warranty gives ...

Reviews: