A n r it s u
4 1
STARTING ANRITSU SCANNERS
1. Start Nemo Outdoor. Do
not
load any previous device configuration if asked.
2. From the Measurement menu, select
Add New Device
.
3. Click on
Scanner
.
4. From the list select:
•
For Anritsu ML8720B:
Anritsu ML8720B UMTS 2100
and click
Next
.
•
For Anritsu ML8720C without the GSM option:
Anritsu ML8720C UMTS 2100
and click
Next
.
•
For Anritsu ML8720C with the GSM option:
Anritsu ML8720C GSM/UMTS
and click
Next
.
•
For Anritsu ML8740A and Anritsu ML8740B without the GSM option:
Anritsu ML8740A/
ML8740B UMTS 2100
and click
Next
.
•
For Anritsu ML8740A and Anritsu ML8740B with the GSM option:
Anritsu
ML8740A/ML8740B GSM/UMTS
and click
Next
.
•
For Anritsu MS2721B DVB-H Analyzer:
Anritsu MS2721B DVB-H
, and click
Next
.
•
For Anritsu MS2721B Spectrum Analyzer:
Anritsu MS2721B Spectrum Analyzer
, and
click
Next
.
5. In the
Scanner Properties
dialog, set the COM Port to the port the scanner is connected to
(ML8720B/ML8720C)/select the USB port (e.g., Anritsu USB1)/or select the Anritsu LAN 1-4
with Anritsu MS2721B DVB-H depending on which IP address was selected for the scanner.
♦
The next step is not valid for the Anritsu ML8740A, Anritsu ML8740B, Anritsu MS2721B
DVB-H, or Anritsu MS2721B Spectrum Analyzer scanner.