background image

Touchless switch

Touchless switch with 10A relay output
Model AE-2400 R

CAUTION:

Important  notes

Read and understand these instructions before
installing device. Before installing this unit, 
disconnect power at circuit breaker or remove fuse 
to avoid shock or damage to the unit. This
device is intended for installation with local 
regulations. It is recommended that a qualified 
electrician perform this operation
Do not install in combination with standard 3-Way
switches or third party remote (slave)  unit. 
Use only in combination with Anigmo AE-S 
remote (slave)unit.
Installation of this switch in proximity of strong EM
interference such as (and not limited to) electrical 
welding machines, inadequately shielded power
supplies, radars etc. could cause inadverted
switch activity.
This switch may not be used in any application in
which the inadvertently changing the switch state
could create a situation where personal injury, death
or property damage may occur.
This unit requires a neutral connection
Do not exceed maximal rated current of the unit

1.

2.

3.

4.

5.
6.

Warranty

All products sold or distributed by Anigmo or any of 
its subsidiaries are guaranteed to be free from defects
in materials and workmanship for the period of 5 years.
This warranty shall extend to the original end 
purchaser only. Anigmo, at its option, shall repair or 
replace any Anigmo product within the Terms of 
Warranty expressed herein, which fails to meet the 
product's specifications. 

This warranty does not extend to product failures or 
defects caused by, or associated with, but not limited
to; failure to install or maintain correctly, unsuitable 
physical or operating environment, accident, force 
majeure, hazard, misuse, electrical supply, 
unauthorised repair, modification or alteration. 

Anigmo will not accept any liability or responsibility 
under the terms of warranty expressed herein for, 
but not limited to; negligence, loss of profit or data or 
damages either material or personal. Mandatory 
liability shall be restricted to the sum equal to the 
purchase of the product.

This product may be protected by following patents 
US 7.531.921, EP 2.038.906, US20090284182, 
US 8.339.062,  EP 2.292.078

Contact

ANIGMO
Anigmoteh d.o.o.
Tehnoloski park 21
1000 Ljubjana
Slovenia, Europe
www.anigmo.com
email: [email protected]

INSTALLATION

1.

WARNING: Turn power OFF at circuit breaker
or remuve the fuse

2.

Connect wires as shown. Refer to wiring
diagrams.

3.

Before installing the unit into a wallbox, set the
desired sensor range if needed.
NOTE: The unit is supplied with its sensing range
set to maximum ( about 10 cm).

4.

Mount the unit into wallbox using claws.
Align before tightening the claw screws

5.

Attach decorativeswitchplate. Allign magnets on the
back of the switchplate with magnets on the unit 
and push.

L
N

LOAD

wallbox

AE-2400 R

N

L

S

L
N

LOAD

wallbox

AE-2400 R

N

L

S

wallbox

AE-S

L

S

wallbox

AE-S

L

S

MULTI LOCATION CONTROL (multiple switches controlling one load)

SINGLE  LOCATION CONTROL (one switch controlling one load)

6.

Restore power at the circuit breaker

WIRING DIAGRAM

Load rating:
240V AC / 50Hz
10A max

F

F*

*

* Connect only to mains

protected with
fuse rated 10A or less.

LOAD

HOT

NEUTRAL

If mounting with screws, first remove both claws,
complete with nuts and screws. Fix the unit
with provided screws only.

Reviews: