background image

 

p.6

 

Anglerfish Crea�ve Ligh�ng

 | 

Anglerfish Trigger V

2.0 

 

Turning Off 

To turn off the trigger simply follow the same procedure as 
required for turning on the unit

.  

Low Battery Indicator 

If the trigger

s batery power is low,

 the trigger’

s menu LED 

will blink 

red

 

and 

blue

 

for five cycles and the trigger will 

enter the sleep mode. To operate the trigger,

 the trigger 

must

 

be charged.

 

Care & Maintenance 

A�er each salt water dive, your trigger should be soaked or 
rinsed in fresh water. The trigger should soak in fresh water 

f

or at least 30 minutes. 

 

Replacing Battery 

The Anglerfish Trigger come with a CR2 batery preinstalled. 
To replace the batery, twist open the cover dome and pull 

Summary of Contents for TRIGGER V3.0

Page 1: ...USER GUIDE ANGLERFISH TRIGGER V3 0 ...

Page 2: ......

Page 3: ... Sheet p ii Anglerfish Crea ve Ligh ng Anglerfish Trigger V2 0 REVISION NUMBER DATE DESCRIPTION REV A DEC 2016 DRAFT REV 0 JAN 2017 ISSUED FOR PRINT REV 1 MAY 2017 UPDATED FOR V2 0 REV2 JAN 2018 UPDATED FOR V3 0 ...

Page 4: ...2 0 Table of Contents TABLE OF CONTENTS I QUICK START 1 FEATURES 2 OPTICAL SYNC CABLE 2 ELECTRONIC SYNC CABLE 3 TURNING ON 4 TURNING OFF 6 LOW BATTERY INDICATOR 6 CARE MAINTENANCE 6 REPLACING BATTERY 6 TROUBLESHOOTING 7 SPECIFICATION 10 COMPLIANCE 10 ...

Page 5: ...rigger V3 0 2 Nikonos bulkhead cap 3 Opera on manual user guide 4 Clear acrylic dome cover 5 CR2 Batery included and installed 6 Op cal or electrical sync cable not included You will need an op cal sync cable or an electronic flash sync cable with a Nikonos 5 pin connector to connect the Anglerfish Trigger to the remote strobe ...

Page 6: ...sensors C Nikonos bulkhead c w cap D Sea Sea type op cal bulkhead E Velcro e groove F Cover Optical Sync Cable The Anglerfish Trigger can trigger a remote strobe via an op cal bulkhead The op cal bulkhead is located on the back of the trigger This feature allows the trigger to connect to A B F D E C ...

Page 7: ...ity single strand cables will result in high atenua on of light and reduc on in the trigger s performance Avoid bending the fiber op cs cable If possible use the shortest cable available Electronic Sync Cable Anglerfish Trigger is also equipped with a NikonosTM cable bulkhead to trigger the remote strobe electronically Only use genuine Sea Sea brand Nikonos cables or similar cables Nikonos bulkhead ...

Page 8: ...th the manufacturer s recommended silicon lubricant Turning On The Anglerfish Trigger is equipped with an accelera on switch that is used to turn the unit on or off To wake up the trigger from sleep mode simply hold the trigger in one hand and strike your wrist against your other hand The impact will wake up the trigger The impact must be axial in the direc on as shown in the figure below ...

Page 9: ...e the trigger turns on For every impact the menu LED will light up purple If the shock due to impact is not strong enough the menu LED will not light up and the trigger will go back to sleep mode in 3 seconds to conserve power This power up sequence prevents the trigger from turning on its own while subject to random shock Once turned on the trigger will automa cally turn off a er 2hrs of opera on ...

Page 10: ...enu LED will blink red and blue for five cycles and the trigger will enter the sleep mode To operate the trigger the trigger must be charged Care Maintenance A er each salt water dive your trigger should be soaked or rinsed in fresh water The trigger should soak in fresh water for at least 30 minutes Replacing Battery The Anglerfish Trigger come with a CR2 batery preinstalled To replace the batery t...

Page 11: ...on The batery cradle has a notch in the botom and will only fit in a correct orienta on inside the housing Only use CR2 batery Any other batery may damage the trigger circuit Troubleshooting Not Turning On If upon impact the purple menu LED does not blink it is likely that the unit s batery has been depleted Batery Notch Housing ...

Page 12: ...ote strobe remove the fiber op c cable from the unit and inspect the small high power LED inside the op cal bulkhead Operate the camera strobe serval mes and see if the LED blinks while the camera strobe fires If the LED does flash bright the fault could be in the op cal cable or the strobe se ngs Make sure you follow the strobe manufacture s se ngs for opera ng the remote strobe via op cal cable Ins...

Page 13: ... strobe and the trigger op cal bulkheads with rubbing alcohol and Q Tips will ensure maximum light transmission and op mal preperformance Some strobes with weak light sensors may not fire while using the op cal cable In this situa on please use the electrical cable Remote Strobe Triggering Randomly It is unlikely that the remote strobe fires randomly However if this happens it means that the Nikonos...

Page 14: ...erged 100 grams 30 grams Compliance Anglerfish Trigger Anglerfish Trigger is constructed from electrical components and parts that are RoHS compliant Anglerfish is a lead fee product This electronic product should not be mixed with general household waste The correct disposal of this product will help prevent any poten al nega ve effect to the environment For disposal please take this product to a des...

Page 15: ... Anglerfish Crea ve Ligh ng Anglerfish Trigger V2 0 QA QC Check List PCB Tes ng Inspec on Menu Func on and Program Test Op cal Trigger Circuit Test Electrical Trigger Circuit Test Hydrotest 980 kPa Serial No ...

Reviews: