20
STEP 3: REMOVE THE FRONT GROUP
THE BELOW PROCEDURE APPLIES FOR F24, F28, F32, F40, F50, F60, F75, F100
1 - Untighten and remove the front group screws one by one with cautious and securely using a pair of tweezers. Screws are black Phillips type.
2 - Put in position the front group spanner 66067102AA and rotate it anti-clockwise so it falls in the correct thread position.
3 - Tighten the front group spanner up to the end-stop. Do not apply more torque after you reached the end-stop.
4 - Pull straightly the front group. As there is an o-ring around the front group mechanics you need to pull with enough force.
5 - Put in a secure area the front group with the spanner on onto the front group holder 66067062AA.
F50 Front group screws location
3
4
5