- 10 -
3220000_inst_GB
ENGLISH
GB
CONVERSION OF ELECTRICITY SUPPLY
Important
The appliance is supplied at an operating vol-
tage 400V/3N (indicated on the sticker ap-
plied to the dataplate); conversion to 230V3~
can be carried out as described below.
Caution - Warning
Before doing any work, cut off the mains
electricity supply.
1)
Pull off the knob
(C)
.
2)
Undo the screws
(D)
and remove the control
panel
(E)
.
3)
Take out screw
(F)
to move the protection
(G)
back
.
4)
Fit the jumper
(N)
to make the electrical con-
nection of the terminals
(O)
.
5)
Move the protection back forwards
(G)
and
lock it by the screw
(F)
.
6)
Replace all when the operation is complete.
7)
Remove the test voltage indicator sticker
from the dataplate and apply the new one to
identify the voltage being used.
Important
On completion of the operation make sure
that there are no malfunctions.
D
A
C
E
D
F
G
N
O