- 14 -
C13143
000.
fm
English
IT
GB
DE
FR
ES
The appliance is supplied at an operating voltage
400V/3N (indicated on the sticker applied to the da-
taplate); conversion to 230V/3 can be carried out as
described below.
Caution - warning
Before doing any work, cut off the mains
electricity supply.
1 - Remove the control panel
(A)
.
2 - Fit the jumper
(B)
to make the electrical connec-
tion of the terminals
(C-D)
.
3 - Change the connections of the terminal board
(E)
as shown in the diagram.
4 - Replace the control panel
(A)
.
5 - Remove the test voltage indicator sticker
from the dataplate and apply the new one
to identify the voltage being used
Important
On completion of the operation make
sure that there are no malfunctions.
CONVERSION OF ELECTRICITY SUPPLY
If the safety thermostat is tripped, the appliance has
to be restored to the initial working conditions as fol-
lows.
1 - Allow the water to cool by 30-40°C
2 - Press the button
(A)
of the safety thermostat to
restore the electricity supply.
RESETTING THE APPLIANCE
A
E
E
230V/3
C
B
D
IDM-39604002200.tif
400V/3N
IDM-39603620000.tif
A
A
A
C13143000.fm Page 14 Thursday, June 12, 2008 3:51 PM