Anest Iwata WA 101 Instruction Manual Download Page 1

Before use, adjustment or maintenance, it is important to read 

this instruction manual very carefully. This manual must be stored 
in a safe place for any future reference that may be necessary. 

IMPORTANT

This automatic spray gun should be operated only by an adequately trained operator for safe use and maintenance of the equip-

ment. Any misuse or handling other than those indicated in this Instruction Manual is not covered by guarantee.  

ANEST IWATA

disclaims all responsibility for any accident or damage caused by failure observing the operational and safety pro-

cedures in this manual. In the interest of user friendliness, this manual contains information in a brief and concise form.

For any additional information you may require regarding the automatic spray gun operations, or if any missing parts or any dam-

age during transportation is found, or details of training courses, please contact your nearest 

ANEST IWATA Company 

(see last

cover page).

Be sure to observe warnings and cautions in this instruction manual.

If not, it can cause paint ejection and serious bodily injury by drawing organic solvent.

Be sure to observe following        marked items which are especially important.

WARNING

Indicates a potentially hazardous situation which, if not avoided, may result in serious injury or loss of life.

CAUTION

Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or pro-

perty damage.

IMPORTANT

Indicates notes which we ask you to observe.  The safety precautions in this instruction manual are the mini-

mum necessary conditions.  Follow national and local regulations regarding fire prevention, electricity and 

safety as well as your own company regulations.

Manufactured by:  

ANEST IWATA Corporation

3176,Shinyoshida-cho, Kohoku-ku, Yokohama, 223-8501 Japan

Instruction Manual

This 

ANEST IWATA

spray guns kit complies to ATEX regulations 94/9/EC, protection level:

II 2 G X Suitable for using Zones 1 and 2.
X marking. Any static electricity discharge from the spray gun is to be diverted to the ground via the conductive air hose as stipulated. 

GB

MJ1207-7EREV

.01

WA 101/WA 200/WA 200WB AUTOMATIC SPRAY GUN 

WA 101R ROUND PATTERN AUTOMATIC SPRAY GUN

LPA 200 HVLP AUTOMATIC SPRAY GUN

ANEST IWATA Italia S.r.l.

Corso Vigevano, 46 - 10155, Torino (Italy)
Tel. d39 011 - 24 80 868 - Fax: +39 011 - 85 19 44
[email protected]

www.anest-iwata.it

ANEST IWATA Iberica

Calle de Les Teixidores, 3-5
08918 - Badalona (Barcelona)
Tel.:+34 93 32 05 993 - Fax.:+34 93 32 05 965
[email protected]

www.anest-iwata.es

ANEST IWATA Deutschland

Mommsenstrasse 5

04329 Leipzig

Telefon: +49 (0)341 241 44 30 - Fax: +49 (0)341 252 55 95

[email protected]      

www.anest-iwata.de

ANEST IWATA Europe S.r.l.

Corso Vigevano, 46 - 10155, Torino (Italy)
Direct Tel. +39 011 - 22 74 402
Fax +39 011 - 22 74 000
[email protected]

www.anest-iwataeu.com

ANEST IWATA Scandinavia 

Ögärdesvägen 6C, 433 30 PARTILLE - Sweden 
Tel. +46 (0)31 - 340 28 60 - Fax +46 (0)31 - 340 28 69
[email protected]

www.anest-iwata.se

ANEST IWATA France 

25 rue de Madrid - 38070 St Quentin Fallavier - France
Tél. +33 (0)4 - 74 94 59 69 - Fax +33 (0)4 - 74 94 34 39
[email protected]

www.anest-iwata.fr

ANEST IWATA  U.K.

Unit 10 Little End Road - Eaton Socon
St. Neots - CAMBRIDGESHIRE
PE19 8JH 
Tel.: +44 (0) 1480 40 54 19  Fax: +44 (0) 1480 21 76 10
[email protected]

www.anest-iwata.co.uk

European Sales Branches:

Summary of Contents for WA 101

Page 1: ...nditions Follow national and local regulations regarding fire prevention electricity and safety as well as your own company regulations Manufactured by ANEST IWATA Corporation 3176 Shinyoshida cho Kohoku ku Yokohama 223 8501 Japan Instruction Manual This ANEST IWATA spray guns kit complies to ATEX regulations 94 9 EC protection level II 2 G X Suitable for using Zones 1 and 2 X marking Any static e...

Page 2: ...8 W200 25 WA25 WA 200WB 0 8 0 031 200WB 08 WA12 WA 200WB 1 0 0 039 200WB 10 WA12 WA 200WB 1 2 0 047 200WB 12 WA12 WA 200WB 1 4 0 055 200WBS1 14 WA15 WA 200WB 1 6 0 063 200WB 16 WA15 LPA 200 1 8 0 071 L200 12 WA12 TECHNICAL SPECIFICATIONS Model Nozzle Air cap Air pressure Air pressure Fluid Air Pattern Weight orifice set at gun inlet inside air cap output consumption width mm in bar PSI bar PSI ml ...

Page 3: ...f done it can cause inflammation of eyes and skin or bodily injury 2 Never exceed maximum operating pressure and maximum operating Temperature 3 Be sure to release air and fluid pressures before cleaning disassembling or servicing If not remaining pressure can cause bodily injury due to improper operation or scattering of cleaning liquid In order to release pressure first stop supply of compressed...

Page 4: ... confirm that there is no leakage WARNING First release air and fluid pressure fully according to item No 3 of Improper use of equipment of WARNING on page 3 Tip of fluid needle set has a sharp point Do not touch the tip of needle valve during maintenance for protection of the human body Be careful not to damage the tip of the fluid nozzle or put your hand on it Only an experienced person who is f...

Reviews: