background image

Installation Instructions

0.3m(1ft)  &  0.6m(2ft)

ValuLine

™ 

 

Antennas Siemens IT1B

Description

In order to change polarization of single polarized antennas

from vertical (factory pre-set) to horizontal. It will be

necessary to rotate the output transition. This is done by

loosening the attachment screws until transition can rotate

freely, rotate the transition 90 deg. clockwise and re-

tightening the attachment screws.

Notice

The installation, maintenance, or removal of antenna

systems requires qualified, experienced personnel.

Andrew installation instructions have been written for

such personnel. 

Antenna systems should be inspected

once a year by qualified personnel to verify proper

installation, maintenance, and condition of equipment.

Andrew disclaims any liability or responsibility for the

results of improper or unsafe installation practices.

2

Bulletin  102217

1

1ft  version  of  Antenna  shown

Horizontally Polarized Application

Timing mark on

transition with timing

mark on mounting ring

(Vertical Polirization)

Loosen  screws  (6  places)  until

transition  can  rotate  freely

then rotate transition hub 90 deg.

untill it "locates" in timing recess.

Vertically Polarized Application

Change of Polarization method

Timing mark on

transition to line up

with timing mark on

mounting ring

(Horizontal

Polarization)

When located, re-tighten to a

torque of 5Nm (3.69 lb-ft)

Transition hub

Note:-

Remove protective blanking plate

and hardware prior to fitting radio.

(Plate hardware to be retained if

radio is required to be remote

mounted)

Reviews: