User’s Manual for Node G
Network Elements
Page 24
M0121A2A.doc
3.2.3. Power
Connection
Before connecting electrical power to the units, the system must be grounded as
described in the previous chapter.
Mains power must be connected at the mains connector. The power supply plug is
included with the Node G.
The correct wiring of the power supply plug is as follows:
figure 3-8 Power supply plug
figure 3-9 Mains connector
A minimum cross section of 1.5 mm
2
is required for the power supply
connection. Each wire must observe the applicable national regulations
regarding loop impedance, voltage drop, and methods of installation.
Make sure to connect the correct voltage to the unit.
)
Note:
Do not connect or disconnect the power cord at the mains
connector while power is on. Turn off mains* power before
connecting the power cord at the units, then, engage mains again.
* Mains power must be interrupted with an external AC breaker. For the AC breaker, observe the
following recommendation:
120 Volt / 20 Amp max. or 240 Volt / 16 Amp, single-phase, 50/60 Hz AC service is
needed, i.e. the external AC breaker should be 20 Amps max. for 120-Volt service or
16 Amps for 240-Volt service.
Mains
Summary of Contents for Node G 930
Page 1: ...ID No 7164491 Page 1 User s Manual for Node G Network Elements ...
Page 12: ...User s Manual for Node G Network Elements Page 12 M0121A2A doc For your notes ...
Page 16: ...User s Manual for Node G Network Elements Page 16 M0121A2A doc For your notes ...
Page 28: ...User s Manual for Node G Network Elements Page 28 M0121A2A doc For your notes ...
Page 52: ...User s Manual for Node G Network Elements Page 52 M0121A2A doc For your notes ...
Page 56: ...User s Manual for Node G Network Elements Page 56 M0121A2A doc For your notes ...
Page 62: ...User s Manual for Node G Network Elements Page 62 M0121A2A doc For your notes ...