Bulletin 7677441 Revision A Page 1 of 2
Andrew Institute offers installation training.
Connector Attachment
For Braided Cable CNT-400
Din Male, Captivated Pin, Clamp-type Body
6.
5.
7.
2.
Straighten first 200.0 mm (7.874") min.
of the cable.
1.
Tools
Connector: 400BPDM-C
4.
3.
Remove 6.5 mm (0.256") of Jacket only.
Connector Body
Cable Attachment
Safety
Knife
Wire
Brush
File
200 mm (7.874”) min.
A
Torque
Wrench
Wrench
16 mm
16 mm
6.5± 0.5 mm
(0.256± 0.020")
Comb braid straight with wire brush;
Fold back braid as shown.
Fold back braid around part A and comb braid as shown,
the braid should be straight and equally spaced after comb.
Cut off the redundant braid as shown.
Taper braid towards center conductor as shown;
According to illustration below to push and rotate slightly part A onto cable without
damaging the braid.
Remove 5.0 mm (0.197") of foil & foam,
exposing the center conductor.
Remove all foam/glue residue from the
center conductor.
Don't damage center conductor
5.0± 0.5 mm
(0.197± 0.020")
Clear all residual braid wire
Diagonal
Pliers