![Andreoli Engineering ATOM 1000 Operator'S Manual Download Page 114](http://html1.mh-extra.com/html/andreoli-engineering/atom-1000/atom-1000_operators-manual_2942479114.webp)
ANDREOLI
ENGINEERING
Operator’s Manual
Self-propelled sprayer ATOM
114/166
7.5
BELTS SERVICE
7.5.1
Chemicals pump drive belt tensioning
To check/adjust belt tensioning follow this procedure.
Stop the engine.
Remove the guard protecting the belt.
Check belt tensioning.
1)
Tensioning screw
2)
Belt
3)
Guide pulley
4)
Fixing screw
5)
Fixing screw
To adjust belt tensioning:
Loosen lightly the fixing screws (4) and (5).
Adjusting the tensioning screw (1) until you reach the correct tension of the belt.
Screw again fixing screws (4) and (5).
Guide pulley (3) is NOT tensioning the belt. Do NOT use this pulley to tension the belt.
To set the right tension on the belts, please refer to the Manufacturer or authorized service.
All service operations MUST be done with engine stopped.
Wait some minutes for cooling of components.
1
4
3
2
4
4
4
1
5
5
5