From the Danfoss Controller screen, I
engage the « automatic loading »
mode but the screen dont let me do it.
Bale carrier
Diagnostic procedure
Verify that the loading arm as been fully extended out
to the right side, and you dont see the « LS Transport »
message on the main screen of the controller
The arm is fully
extended out to the
right, but i still see
the « LS TS » error
message on the main
screen.
Inspect the « LS
Transport » sensor
and make sure it is
powered and
functionnal when the
arm is extended.
The arm is fully extended
out to the right and the
« LS_TS » message DO NOT
appear on the main screen.
Go in the setting of the
controller under section
« bale corrector » and reset
the bale that is on the unit
if it show that it is fully
loaded. Often this is cause
by skipping some step
during the « unloading
mode »
When i engage the
« automatic loading »
mode, the computer screen
bring me automatically in
manual mode.
When i engage the
« automatic loading »
mode, the screen remain in
the « main screen menu »
You need to position
manually every Stackpro
movement accordingly so
at least one sensor of each
possible movement is
activate. It wont engage the
« automatic loading »
mode if one function is in
mid-run position.
9
Summary of Contents for STACKPRO 5400
Page 27: ...List of all sensor and their location 27 ...
Page 28: ...List of all sensor and their location 28 LS_BR_R LS_BR_E ...
Page 29: ...List of all sensor and their location 29 ...
Page 30: ...List of all sensor and their location 30 LS_CH ...
Page 53: ...List of all sensor and their location 53 ...
Page 54: ...List of all sensor and their location 54 LS_BR_R LS_BR_E ...
Page 55: ...List of all sensor and their location 55 ...
Page 56: ...List of all sensor and their location 56 LS_CH ...
Page 58: ...58 Electric diagram 7200 2 0 ...