50
PROCEDURE REF# A-RBM-030
Understanding the screen message restriction
When controlling the machine in « manual mode » through
the Danfoss touchscreen controller, you will receive
notification about existing « restriction » that could block you
of doing a specific movement.
It if important to understand how to read those notification
RAISING LOADING ARM IMPOSSIBLE
LS_PO_R (ON)
LS_TP_E (ON)
OK
Let’s
say you want to raise the loading arm up manually, and
then this message appear.
Condition written are the sensor that should be (ON) in order
to let you do the movement you are looking for.
The color GREEN or RED indicate if the condition is actually
met. In this case, the sensor LS_PO_R mean the front pusher
is not retracted to
it’s
initial position, so it is RED.
You need to bring the pusher back to the front to be able to
raise the arm.
Summary of Contents for RBMPRO
Page 18: ...18 PROCEDURE REF A RBM 001 hydraulic diagram...
Page 33: ...33...
Page 35: ...35 Arm s top view from the outside PROCEDURE REF A RBM 020 Wrist...
Page 38: ...38 Back of the trailer Stopper rollers PROCEDURE REF A RBM 023 Stopper rollers...
Page 43: ...43 PROCEDURE REF A RBM 014 Danfoss controller Home Screen...
Page 44: ...PROCEDURE REF A RBM 015 Danfoss controller Reset bales loaded Adjust with touch screen...