35
Operator's Guide – Round Bale Wrapper IFX720
Anderson Group
it has been adjusted correctly.
Figure 49 — Adjusting the Automatic System
(Spool Measurement)
6. If the measurement is not 3 mm (1/8 in.):
l
Slightly unscrew the two bolts on the plate (Figure
50).
l
Use the lever to move the automatic system's front
rod ( Figure 50 ). You should obtain a space of 3
mm (1/8 in.) (Figure 49). The plate should remain
at the end of the slot (Figure 48).
l
Tighten the two bolts (Figure 50).
Figure 50 — Adjusting the Automatic System
(Moving the Plate)
7. Because this adjustment must be very exact,
repeat steps 1–5 to make sure the adjustment was
made correctly and the space measures 3 mm
(1/8 in.).
— Adjusting the Spring on the Automatic System
This adjustment may be necessary if the pusher does not
come back at the end of the pushing cycle and you have
checked all the other components of the automatic
system. To adjust the spring:
1. Check the position of the spring bracket. It
should be at a 45° angle with the plate, which
will normally put the correct tension on the
spring bracket.
Figure 51 — Adjusting the Spring on the
Automatic System
2. Loosen the bolt on the spring bracket slightly and
move the bracket to stretch the spring a bit more.
Tighten the bolt.
NOTE:
Do not tighten the spring too much, or
the pusher will come back before the end
of its travel.
Adjusting the hoop drive wheel
The hoop can slow down or stop due to slippage between
the drive wheel and hoop. Increase the tension on the
spring that secures the wheel by tightening the nut on the
threaded rod (Figure 52).