background image

SAFETY INSTRUCTIONS

 WARNING

1. 

120 Volts may cause serious injury from electric shock. Disconnect electrical power before starting installation or servicing. Leave power 
disconnected until installation/service is completed.

2. 

Dropping may cause personal injury or equipment damage. Handle with care and follow installation instructions.

 CAUTION

1. 

Read all instructions before beginning installation.

2. 

Improper installation may cause property damage or injury. Read instructions before installation, service or maintenance.

3. 

Do not use in pool applications. Pool chemicals can damage the dehumidifier.

4. 

Do not use solvents or cleaners on or near the circuit board. Chemicals can damage circuit board components.

5. 

Wait 24 hours before running the unit if it was not shipped or stored in the upright position

6. 

Do not use dehumidification to prevent window condensation in the winter. To address window condensation, use ventilation to lower 
indoor humidity in the winter.

READ AND SAVE THESE INSTRUCTIONS

DEHUMIDIFIER 

CONTROL

ON/OFF

 BUTTON  

USED TO TURN 

DEHUMIDIFIER ON 

AND OFF

UP/DOWN

 

BUTTONS USED TO 

CHANGE HUMIDITY 

SETTING

MODE BUTTON USED 

FOR OPTIONAL 

VENTILATION FEATURE

INLET

FILTER ACCESS DOOR

DRAIN

POWER 

SWITCH

OUTLET

Model A130F Dehumidifier

Installation and Operating Instructions

1

Summary of Contents for A130F

Page 1: ...ications Pool chemicals can damage the dehumidifier 4 Do not use solvents or cleaners on or near the circuit board Chemicals can damage circuit board components 5 Wait 24 hours before running the unit...

Page 2: ...RATION 8 Using the Dehumidifier Control 8 Using the Model A77 Remote Control 8 TROUBLESHOOTING 9 Table 1 Diagnostic Codes 9 Table 2 Troubleshooting Guide 10 SERVICE PARTS 11 LIMITED WARRANTY 12 SPECIF...

Page 3: ...rvice access will require the removal of the side panel shown Allow sufficient space for service on this side of the unit Always install the dehumidifier in a condensate pan when locating in or over a...

Page 4: ...l surface is required to ensure proper drainage from the dehumidifier CONDENSATE PAN CONDENSATE PUMP AND FLOAT SWITCH A condensate pan is recommended when locating in or above a finished space or susp...

Page 5: ...tighten to secure 4 Restore dehumidifier power There is a delay of three minutes after restoring power before the dehumidifier will respond to the control 5 Go to REMOTE CONTROL on page 6 to configure...

Page 6: ...r for the installed application Use the UP or DOWN buttons to select items and use MODE to switch to the next set up option To exit installer set up all options must be scrolled through using the MODE...

Page 7: ...red the dehumidifier and all of the wired components will turn on and off during Installer Test Mode to demonstrate that all are properly operating Installer Test Mode lasts for four 4 minutes If the...

Page 8: ...he setting the blowers turn off and the display returns to showing the RH setting 4 The dehumidifier will sample again after the number of minutes selected during the Air Sampling portion of the Syste...

Page 9: ...sensor temperature while also displaying ON Scroll through these values and by using the UP DOWN arrow buttons 7 Record values and call Technical Support Cycle Power E5 High Temperature Thermistor Fai...

Page 10: ...ty condensate pan If no float switch installed check that the jumper is installed at the float switch terminals on the control board Coil frosting defrost Lack of or reduced airflow Check dehumidifier...

Page 11: ...5574 Not Shown Condensate Pump with Tubing 4856 Alert Light 5818 No Part Description Part No 1 Filter 16 x 19 x 1 5769 2 Internal Control Board Deh 5444 3 User Interface Assembly Deh 5738 4 Door Filte...

Page 12: ...LIMITED IN DURATION TO THE AFORESAID FIVE YEAR PERIOD RESEARCH PRODUCTS CORPORATION S LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OTHER THAN DAMAGES FOR PERSONAL INJURIES RESULTING FROM ANY BREA...

Reviews: