background image

 

User Manual                                               

15-20 

Chapter 3  Installation 

 

3.1 Appearance checking 

1)

 

After you received the devices, firstly you should check whether the 
packing is well, otherwise, please contact with our company or the 
local agent in time so as to solve the problem. 

2)

 

After opening the box, you should check whether the device and the 
fittings are correct and well according to the incasement list, 
otherwise please contact with our company or the local agent. 

3.2 Installation process 

1)

 

Firstly place the device at a steady position, the working environment 

should be dry, tidy, ventilative, and the temperature should be 

reasonable. 

2)

 

Check whether the clock and time slots control switch are right 

before connecting the power supply. The device is set internal 
oscillator when leave factory, if it is point-to-point application, please 

adjust one side internal oscillator, the other side line clock, which 
will follow the time slots setting automatically. 

3)

 

Check the power collocation of FE1/V.35 interface converter, if it is 

DC model, please pay attention to the voltage value and polarity, 
then connect the power supply referring to this manual.   

4)

 

Please test the device before using: open the power switch, indicator 
(PWR) is bright, which show the power supply is normal; when you 
don’t connect anything, PWR(Green)

E1LOS(Red) are all bright, the 

others are off. 

5)

 

Shut down the power, connect the E1 cables and V.35 cables, set the 
clock and time slots control switch correctly referring to this manual, 

then open the power switch, the device will turn into normal working 
state. 

3.3 Installation notice proceeding 

1)

 

During the process of transportation and installation, the device 
should be protected against vibration and mechanical damages. 

2)

 

Please examine the voltage value and whether the polarity is in 
accord with the mark on the rear panel before electrifying, or else the 

Summary of Contents for FE1/V.35

Page 1: ...FE1 V 35 Interface Converter Version V3 2 4 Date 5 12 2005...

Page 2: ...on 5 2 1 Front Panel 5 2 1 1 Indicators 5 2 2 Back Panel 6 2 2 1 Power Supply 6 2 2 2 E1 Interface 7 2 2 3 V 35 Interface 7 2 2 4 Time Slots Settings 9 2 2 5 Settings of SW 11 Chapter 3 Installation 1...

Page 3: ...2 Characteristics y Dithering tolerance and dithering transmission characteristic of E1 channel have high performance which is superior to industry standard y Support CAS and CCS mode y Support CRC 4...

Page 4: ...23 standard Impedance 75 unbalanced 120 balanced Clock mode Internal clock default External clock Line clock Voltage AC110V AC 240V DC 48V DC 48V DC 24V Power supply Power consumption 5W Environment W...

Page 5: ...f E1 frame lost Bright when local device E1 frame lost Blinking when remote device E1 frame lost Local has higher priority y TXD Green Indicator of V 35 data transmittal Blinking when V 35 data transm...

Page 6: ...Back panel of FE1 V 35 Interface Converter DC 2 2 1 Power Supply AC socket AC 220V input DC socket If the power supply is 48V connect the device pole with power 48V pole the device pole with power GN...

Page 7: ...interface 75 un balanced interface Table 2 Definition of E1 75 120 switch 75 unbalanced E1 interface connector are BNC connector RX indicate E1 input TX indicate E1 output 120 balanced E1 interface c...

Page 8: ...ipped DB25M M34F cable NOTE Connect with DCE device by intercross cable facture of intercross cable defined as below note that some DCE device pin assignment are different A B DB25 Pin Definition DB25...

Page 9: ...O 0 NO 31 bit corresponding E1 TS0 TS31 ON when opening up the corresponding time slot OFF when closed Fig 7 Bottom panel of FE1 V 35 Interface Converter Settings of time slot defined as below table s...

Page 10: ...TS22 is invalid ON 23 ON TS23 is available OFF TS23 is invalid ON 24 ON TS24 is available OFF TS24 is invalid ON 25 ON TS25 is available OFF TS25 is invalid ON 26 ON TS26 is available OFF TS26 is inv...

Page 11: ...receiving E1 signal under this settings the device can auto follow the opposite device Time slot settings if the opposite device is INTERNAL clock External clock OFF OFF The clock obtains from V 35 p...

Page 12: ...SW SW 4 SW 5 SW 6 are LOOP Setting REM only can used in framed E1 defined as below SW DEFINITION SPECIFICATION DEFAULT ON Loop SW 4 Loop local data back ANA OFF Work normally OFF ON Loop SW 5 Loop li...

Page 13: ...bright Green Loop line back if E1 is framing the led of test in the remote device is blinking OFF OFF ON OFF OFF OFF OFF OFF Not bright Blinking Green Loop the remote device the led of test in the re...

Page 14: ...e device time slot settings Only used in LINE clock and the opposite device INTERNAL clock SW Definition Specification Default ON unfollow SW 8 Follow OFF follow ON Table 12 Settings of follow NOTE Th...

Page 15: ...e side internal oscillator the other side line clock which will follow the time slots setting automatically 3 Check the power collocation of FE1 V 35 interface converter if it is DC model please pay a...

Page 16: ...optimal status before leaving factory please don t take apart the device privately if non technicians of our company 4 When the device has failure you can make sure the failure range through self loop...

Page 17: ...scillator loopback the input and output ports by E1 cable if this indicator is off then mainly examine the E1 cable Exclusion Examine whether the receiving and transmitting E1 cables are inverse if so...

Page 18: ...al clock Exclusion Two internal clocks will lead to some data lost two line clocks may lead to the line not on hook adjust the clock to make sure only one device provide clock in one line y Trouble ph...

Page 19: ...ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON 6 ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON 7 ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON 8 ON...

Page 20: ...N ON ON ON ON ON 6 ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON 7 ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON 8 ON ON ON ON ON ON ON ON ON ON ON ON...

Reviews: