10
Gas hose
Air compresser
Input cable
CUT40i
2 5
3 0
2 0 3 5
1 5 4 0
CURRENT(A )
1-phase
Work piece
Ground cable
Grounding
Cutting torch gas-electric connector
Control cable
Torch
Fig. 4-4-1: Output socket
4-5 Installation and operation
Warning!
An electric shock can be fatal. If the machine is plugged into the mains
electricity supply during installation, there is high risk of very serious injury and
damage. Do not use the functions described here until you have read and
completely understood “Safety Rules” in the beginning. Only carry out work on the
machine when
- the mains switch is in turn-off position,
- the machine is unplugged from the mains.
CUT40i cutting machine wire diagram as Fig. 4-5-1:
Fig. 4-5-1: Installation of CUT40i
Input power supply cable installation
Please note the size of fuse and circuit breaker in the table below are for reference only.
Fast plug
-
in type