AMD2000 Series - Servo Drive - User Manual
62
DS619-0-00-0019 - Rev 0
ANCA Motion
Typical Connection Examples
7.3.12.3.2
24V
(X4 Pin 20)
AMD2000
Example - PLC
DSP
DO-XX
DI-XX
AMD2000
Relay
DO-XX
24V
(e.g. X4 Pin 20)
24 V
(External)
Load
7.4
Motor Brake Control
A motor brake can be connected to any of the digital outputs as previously described. The maximum current
allowable is 500mA sink between all 6 digital outputs. Failure to observe this rating will result in damage to the
drive.
See section
7.4 Motor Brake Control
for connection details.
7.5
Serial Communication Port
The Serial Communication Port is not enabled in this Catalogue Number.
7.6
Ethernet Interface
7.6.11
EtherCAT®
2
AMD2000 supports the EtherCAT protocol
with ‘Servo Profile over EtherCAT’ (SoE) capability based on the
IEC61800-7 standard. This protocol provides deterministic communication over a standard 100Mbit/s (100Base-
TX) Fast Ethernet (IEEE802.3) connection. This makes it suitable for the transmission of control and feedback
signals between the AMD2000 and other EtherCAT enabled controllers.
2
EtherCAT® is a registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany