6
Continuation of Motor Power Cable Shielding
6.8.12.2
Add a metal P-Clip or equivalent to the armature cable at a location that is close to the
motor for earthing the shield.
In order to add this part to the Armature Cable, remove a sufficient amount of outer sheath
in order to make direct contact with the exposed metal braid.
Ensure that the metal braid is not damaged in this process.
Remove the painted to expose the bare metal beneath. The shield is required to have a
good electrical connection to the machine earth.
Motor
Metal P-Clip
Exposed Metal Braid
Armature Cable from 3A
or 9A Drive
Figure 6-12 Armature Cable Shield Termination at Motor End
The below graphic shows a typical Earth Bar installation that may exist on the cabinet.
Connect the Protective Earth wires to the Earth bar as shown. Each protective earth Wire will
be from a drive in the cabinet.
Protective Earth Wires to
the Drive Earthing points
(see above pictures for
locations)
Factory Earth Wire