Technical Data
ANCA Motion
DS619-0-00-0019 - Rev 0
165
12
12.6
Environmental Specifications
Catalogue Number
D2003-2S1-A
D2009-2S1
Attribute
Qualification
12.6.11
Storage
Ambient Temperature
-20 to +65° C
Relative Humidity
5 to 90%
12.6.12
Transport
Ambient Temperature
-20 to +65° C
Relative Humidity
90% at 40° C
Mechanical vibration
5.9m/s
2
maximum
12.6.13
Installation and Operation
Permissible Ambient Temperature at rated
continuous current
I
aN
0 to +50° C
Maximum Ambient Temperature with de-rating
15
+55° C
Relative Humidity
5 to 85% non-condensing
Mechanical vibration
5.9 m/s2 maximum
Unusual environmental conditions
Not provided beyond 60146-1-1
Maximum installation/operating altitude (with respect
to mean sea level)
1000
12.6.14
Physical Characteristics
Degree of Protection
IP20 in accordance with 60529
Mounting position in Operation
Vertical
Device Weight
1.25kg
2kg
Height (mm)
206
182
Width (mm)
43
60
Depth (mm)
189
185
12.6.15
Cooling
Fan Cooled
No
Yes
Heat generation @ full rated continuous current
2
31 W
80 W
15
De-rating is applied to the maximum rated continuous current
I
aN
from 100% at 50°C down
to 50% at 60°C
2