Fault Tracing
ANCA Motion
DS619-0-00-0019 - Rev 0
155
11
Severity
Error
Absolute Encoder Alignment Error
E0406
Description
Absolute encoder used for field orientation initialisation has failed to latch an alignment angle.
Possible causes for this error are:
1. Encoder is faulty. Power cycling the drive/encoder may resolve the issue.
2. Drive is faulty. Please contact ANCA Motion for support.
Severity
Error
Field Orientation Alignment in Progress
I0409
Description
Field Orientation Alignment is in progress - active stimulus signal (current) has been
commanded to the motor.
Severity
Info
Acceleration Observer Excessive Movement
E0411
Description
Motor movement exceeded tolerance while executing acceleration observer field orientation.
Possible causes for this error are: 1. Incorrect motor poles configured. 2. Incorrect motor
phase sequence. 3. Incorrect motor encoder line count configured. 4. Incorrect motor encoder
polarity configured.
Severity
Error
Acceleration Observer Current Control Error
E0412
Description
Sensed motor current is not following the Acceleration Observer alignment current with
sufficient accuracy, Possible causes for this error are:
1. Poorly tuned current loop.
2. DC bus voltage too low.
3. Motor armature cable is disconnected.
4. Motor is faulty.
5. Drive is faulty. Please contact ANCA Motion for support.
Severity
Error
Acceleration Observer Excessive Velocity
E0413
Description
Excessive velocity detected while acceleration observer is executing. Possible causes for this
error are:
1. Incorrect motor poles configured.
2. Incorrect motor encoder line count configured.
3. Stimulus frequency is too low.
4. Stimulus current is too high.
Severity
Error
Acceleration Observer Torque Response Amplitude Low
E0414
Description
The fundamental frequency component of the torque response is below the minimum
amplitude threshold. Possible causes for this error are:
1. Stimulus frequency is too high.
2. Stimulus current is too low.
Severity
Error
Acceleration Observer Torque Response Amplitude High
E0415
Description
The fundamental frequency component of the torque response is above the maximum
amplitude threshold. Possible causes for this error are:
1. Stimulus frequency is too low.
2. Stimulus current is too high.