Fault Tracing
ANCA Motion
DS619-0-00-0019 - Rev 0
153
11
Amplifier I2R Warning
W0321
Description
Residual heat within the drive power stage (amplifier) exceeds the warning level. Possible
causes for this error are:
1. Application is outside the specification for the drive: too demanding.
2. Current controller is poorly tuned.
3. Field orientation alignment is inaccurate (possible encoder fault).
4. Drive is faulty.
Please contact ANCA Motion for support.
Severity
Warning
Motor I2T Warning
W0322
Description
Motor current is higher than the specified load threshold. Possible causes for this error are:
1. Load on axis is above configured threshold.
2. Axis has crashed or jammed.
Severity
Warning
Motor I2R Warning
W0324
Description
Residual heat within the motor exceeds the warning level. Possible causes for this error are:
1. Application is outside the specification for the motor: too demanding.
2. Current controller is poorly tuned.
3. Field orientation alignment is inaccurate (possible encoder fault).
4. Motor is faulty.
Severity
Warning
Motor I2R Overload
E0325
Description
Residual heat within the motor exceeds the thermal limit. Possible causes for this error are:
1. Application is outside the specification for the motor: too demanding.
2. Current controller is poorly tuned.
3. Field orientation alignment is inaccurate (possible encoder fault).
4. Motor is faulty.
Severity
Error
Positive Position Hard Limit
E0330
Description
Position hard limit in the positive direction has been exceeded. Possible causes for this error
are:
1. Error limit is enabled before the axis has been successfully homed.
2. Master or other High Level Function has commanded the drive to a position that
exceeds the positive position limit.
3. Drive has experienced a fault which has resulted in a runaway event.
Severity
Error
Negative Position Hard Limit
E0331
Description
Position hard limit in the negative direction has been exceeded. Possible causes for this error
are:
1. Error limit is enabled before the axis has been successfully homed.
2. Master or other High Level Function have commanded the drive to a position that
exceeds the negative position limit.
3. Drive has experienced a fault which has resulted in a runaway event.
Severity
Error
Positive Velocity Hard Limit
E0332
Description
Positive velocity hard limit has been exceeded. Possible causes for this error are: