Positive Position Soft Limit
E0304
Description
Position soft limit in the positive direction has been exceeded. Possible causes for this error
are:
1. Error limit is enabled before the axis has been successfully homed.
2. Master or other High Level Function have commanded the drive to a state (position &
velocity) where it will be unable to decelerate before exceeding the positive position limit.
3. Drive has experienced a fault which has resulted in a runaway event.
Severity
Error
Negative Position Soft Limit
E0305
Description
Position soft limit in the negative direction has been exceeded. Possible causes for this error
are:
1. Error limit is enabled before the axis has been successfully homed.
2. Master or other High Level Function have commanded the drive to a state (position &
velocity) where it will be unable to decelerate before exceeding the negative position
limit.
3. Drive has experienced a fault which has resulted in a runaway event.
Severity
Error
Positive Position Dead stop
E0306
Description
Position positive dead stop input is active.
Severity
Error
Negative Position Dead stop
E0307
Description
Position negative dead stop input is active.
Severity
Error
Instantaneous Current Limit Exceeded
E0308
Description
One or more of the motor phase currents has exceeded the instantaneous limit. Possible
causes for this error are:
1. Instantaneous current limit is configured too low given the unified current limit.
2. Current loop is poorly tuned.
3. Motor is faulty.
4. Drive is faulty. Please contact ANCA Motion for support.
Severity
Error
Amplifier I2R Overload
E0309
Description
Residual heat within the drive power stage (amplifier) exceeds the thermal limit. Possible
causes for this error are:
1. Application is outside the specification for the drive: too demanding.
2. Current controller is poorly tuned.
3. Field orientation alignment is inaccurate (possible encoder fault).
4. Drive is faulty. Please contact ANCA Motion for support.
Severity
Error
Motor I2T Overload
E0320
Description
Motor current is consistently higher than the specified load threshold. Possible causes for this
error are:
1. Load on axis is above configured threshold.
2. Axis has crashed or jammed.
Severity