LOGS CONTROL
It is possible to use the digital input to start and/or pause the logs of the other input channels. Once configured in the "Logs Control" mode, each
selected edge will start or stop the process of in-memory logs. As in the "Event Log" mode, detected events will only act after the configured
debounce
time expires. Thus, the start/pause of the logs will be performed with the
debounce
time delay.