RK-350

 

Ref. RK-350

QUICK START GUIDE

Thank you for choosing 

Analog Way

 and the 

RK-350

. By following these simple steps, you should be able 

to setup and use your powerful remote Control Keypad within minutes. Discover the 

RK-350

 extensive 

capabilities and intuitive interface while configuring your first show, and unleash your creativity for a new 

experience in show and event management by 

Analog Way

.

• 1 x 

RK-350 (RK-350)

• 1 x Power supply cord

• 1 x DB9 (M/F) cable

• 1 x Carrying case

• 1 x Quick Start guide*

* The Quick Start guide is also available on 

www.analogway.com

WHAT’S IN THE BOX

RK-350 SETTINGS

•   The 

RK-350

 automatically detects the right versions  of 

the product to control. Connect the DB9 cable supplied 

or an Ethernet crossover cable using the same protocol 

as the connected unit.

• To control the following Seamless Switchers:

Control Mode

Seamless 

Mixer

Seamless 

Matrix

Quadravision

EKS550

x

x

x

QMX150

x

SMX250

x

QVU150

x

PLS350

x

x

SPX450

x

x

Navigation Menu:

To access the 

RK-350

 menu, press the 

EXIT/MENU

 button 

in the control section. To highlight items in the menu which 

will appear on the VFD screen, turn the scroll knob left or 

right to the desired menu item. When you have reached 

the desired menu item, press the 

ENTER

  button  in  the 

control section to access that menu function. 

Pressing the 

ENTER

 button when a selection has been made 

sets  the  value  to  that  selection  in  the 

RK-350 

memory. 

When all settings have been made, press the 

EXIT/MENU

 

button to exit sub-menus and return to the main menu.

IMPORTANT:

  simply  selecting  a  menu  item  will  not  set  

it to that value. Be sure to press the 

ENTER

 button when 

parametering the menu items.

Once you have connected your 

RK-350

 to your switcher, 

configure the connection settings on both devices.  

For a serial connection, select RS232 from the RS232/LAN 

menu on both devices. (In 

CONTROL

 menu)

For a LAN connection, select LAN from the RS232/LAN menu 

on both devices (In 

CONTROL

 menu), and configure each 

device with a unique IP in the 

LAN setup > RK-350

 address 

menu. The default IP on the 

RK-350

 is 

192.168.2.141

Next, enter the IP of the device you wish to control in the 

Lan Setup > Device address menu

.

Once  your  settings  are  correct,  the 

RK-350

 will begin 

to synchronize with the device, and you will be ready to 

begin. (Wait a minute).

Button color usage:

Solid red:

#1 = Source is on the Program output

#2 = Freeze enable

#3 = Stand-by button

#4 = Mute enable

Solid green:

Solid orange:

Blinking red:

Blinking green: 

#1 = Source is on Preview

#2 =  Function available for modification

Unlocked sources / Shifted keys

Layer/source selected or is currently active 

on the Program output
Layer/source selected or is not currently 

active on the Program output