17
www.analogway.com
USER MANUAL
USER MANUAL
USER MANUAL
USER MANUAL
USER MANUAL
USER MANUAL
USER MANUAL
USER MANUAL
2.1.7
Environmental specifications for all Picturall models
Picturall Twin Compact Mark II and Quad Compact Mark II
:
• Dimensions without rack mount and handles: W 4
40 x H 88 x D 640 mm
• Dimensions with rack mount and handles: W 482 x H
88 x D 680 mm
• Product Weight:
17,5kg
Picturall Quad Mark II and Pro Mark II
• Dimensions without rack mount and
handles: W 440 x H 177 x D 645 mm
• Dimensions with rack mount and handles: W 482 x H
177 x D 694 mm
• Product Weight:
Quad Mark II
: 20,8g
–
Pro Mark II
(fully loaded): 24,5kg
General
:
• Cooling air flows from front side to rear.
• Max ambient operating t
emperature: < 40°C (< 104°F).
• Operating temperature: 0 to +40°C / +32°F to +104°F
•
Storage temperature: -10 to +60°C / +14°F to +140°F
• Operating humidity: 10 to 80% (non condensing)
• Input voltage range: 100
-240 VAC autosensing, 50/60 Hz 7A
• Max consumption:
660W
Safety standard
:
• IEC/EN/UL 62368
-1
• CSA C22.2#62368
-1
Electromagnetic compatibility
:
• EN55032
• EN55024
• EN61000
-3-2
• EN61000
-3-3
• CFR47 Part 15
• ICES
-003
Environment
:
• RoHS
• WEEE
Caution:
Should the unit lose power unexpectedly; unsaved settings may be lost.