91
USER MANUAL
USER MANUAL
USER MANUAL
USER MANUAL
USER MANUAL
USER MANUAL
USER MANUAL
USER MANUAL
1 7
User Maintenance and Troubleshooting
17.1
User Maintenance
–
Air filter
Tip
: For optimal performance, this air filter must be cleaned by the user regularly (once a year).
The LivePremier unit is equipped with a removable air filter at the front of the unit.
Tools:
Phillips screwdriver size 2, duster or vacuum.
1.
Turn the unit off and unplug mains.
2.
Remove the four screws on the front panel.
3.
Using both hands, gently pull the front panel on a straight axis.
4.
Gently tilt it down until mechanical stop.
The front panel is in safe still position.
5.
Pull the air filter and take it out from the unit.
6.
Carefully clean the air filter with a duster or vacuum.
7.
When the air filter is clean, gently put it back in place.
8.
Gently tilt up the front panel until it is aligned.
9.
Gently push the front panel back in place on a straight axis.
10.
Set the screws back in place.
The air filter is cleaned and the unit is ready for use.
17.2
Troubleshooting
The Web browser cannot access the WebRCS
-
Make sure to use correct network cables and that they are free from defects. (Crossover or
straight cable as required).
-
Check the IP address of the control computer. It must have a unique IP address on the same
network as the LivePremier unit.
-
Temporarily disable any other networks on the computer, such as turning off the Wi-Fi
connection.
-
Refresh the browser.
-
Close and restart the browser.