background image

6

DEMO MANUAL DC3018A

Rev. 0

DC3018A DEMO BOARD

(WITH EMI FILTER INSTALLED)

3.3V INPUT TO 1.2V OUTPUT AT 10A, f

SW

 = 2MHz

CLASS 5 PEAK LIMIT

MEASURED EMISSIONS

AMBIENT NOISE

FREQUENCY (MHz)

0

10

20

30

40

50

60

70

80

90

100

110

–20

–10

0

10

20

30

40

50

60

AMPLITUDE (dBµ

V/m)

dc3018a ETR01

EMI TEST RESULTS

Conducted EMI Performance (CISPR25 Conducted 

Emission Test with Class 5 Peak Limits) 

Radiated EMI Performance (CISPR25 Radiated 

Emission Test with Class 5 Peak Limits) 

Radiated EMI Performance (CISPR25 Radiated 

Emission Test with Class 5 Peak Limits) 

DC3018A DEMO BOARD

(WITH EMI FILTER INSTALLED)

3.3V INPUT TO 1.2V OUTPUT AT 10A, f

SW

 = 2MHz

HORIZONTAL POLARIZATION

CLASS 5 PEAK LIMIT

MEASURED EMISSIONS

AMBIENT NOISE

FREQUENCY (MHz)

0

100

200

300

400

500

600

700

800

900

1000

–20

–10

0

10

20

30

40

50

60

AMPLITUDE (dBµ

V/m)

dc3018a ETR02

DC3018A DEMO BOARD

(WITH EMI FILTER INSTALLED)

3.3V INPUT TO 1.2V OUTPUT AT 10A, f

SW

 = 2MHz

VERTICAL POLARIZATION

CLASS 5 PEAK LIMIT

MEASURED EMISSIONS

AMBIENT NOISE

FREQUENCY (MHz)

0

100

200

300

400

500

600

700

800

900

1000

–20

–10

0

10

20

30

40

50

60

AMPLITUDE (dBµ

V/m)

dc3018a ETR03

Summary of Contents for DC3018A

Page 1: ...ontinuous mode The Efficiency vs Load graph shows the efficiency and All registered trademarks and trademarks are the property of their respective owners PERFORMANCE SUMMARY the power loss of the circ...

Page 2: ...the voltage on the SSTT turret Observe the switching waveform by contacting a second voltage probe set to 1V scale to the SW node of UI pins 6 7 8 and 9 as shown in Figure 1 5 If pulse skip mode is de...

Page 3: ...E3 E5 E12 E11 E13 E7 E8 E2 E20 E1 E17 E19 E18 E10 E9 MP4 E4 E6 E16 E15 E21 MP2 MP1 E14 R7 R12 C3 C2 C5 C6 L1 U1 C4 C11 C10 C20 C23 C22 C21 C19 C12 R10 R13 R9 GND GND GND PS1 AM1 VIN VIN SNSE SNSE SNS...

Page 4: ...sponse QUICK START PROCEDURE CIRCUIT SCHEMATIC Efficiency vs Load Current 1 2V 12 5A Step Down Converter Load Transient Response Forced Continuous Mode 3 3VIN TO 1 2VOUT LOADSTEP 2 5A TO 10A 1A s 20 s...

Page 5: ...5 DEMO MANUAL DC3018A Rev 0 BOARD PHOTO...

Page 6: ...Peak Limits Radiated EMI Performance CISPR25 Radiated Emission Test with Class 5 Peak Limits DC3018A DEMO BOARD WITH EMI FILTER INSTALLED 3 3V INPUT TO 1 2V OUTPUT AT 10A fSW 2MHz HORIZONTAL POLARIZAT...

Page 7: ...de The PWM modes of operation are either pulse skip or forced continuous See the LTC3311S data sheet for more detailed information The maximum allowable operating frequency is influ enced by the minim...

Page 8: ...Q200 MURATA GCM155R71C224KE02D 6 1 C21 CAP 1 F X5R 10V 20 0402 MURATA GRM153R61A105ME95D 7 2 C22 C23 CAP 0 1 F X7S 16V 10 0201 MURATA GRM033C71C104KE14D 8 1 L2 IND 100 AT 100MHz FERRITE BEAD 25 8A 6m...

Page 9: ...REMAINS THE CUSTOMER S RESPONSIBILITY TO VERIFY PROPER AND RELIABLE OPERATION IN THE ACTUAL APPLICATION COMPONENT SUBSTITUTION AND PRINTED CIRCUIT BOARD LAYOUT MAY SIGNIFICANTLY AFFECT CIRCUIT PERFOR...

Page 10: ...isclose or transfer any portion of the Evaluation Board to any other party for any reason Upon discontinuation of use of the Evaluation Board or termination of this Agreement Customer agrees to prompt...