Installation Guide
CB-MVP-WCS52
Rough-In Box for MVP-WCS-52 Wall Charging Station
Overview
The CB-MVP-WCS52 Rough-In Box allows the MVP-WCS-52 (5.2" Modero
ViewPoint Wall Charging Station) to be installed in a solid surface (e.g., wall or
podium).
Specifications
WARNING:
INSTALLER, LEAVE A GAP BETWEEN THE STUD AND
ROUGH-IN BOX TO ACCOMMODATE THE DRYWALL/SHEETROCK.
This gap allows the installation of the drywall/sheetrock after the
CB-MVP-WCS52 has been mounted onto the beams. The stud notching and
Rough-In Box installation must be done prior to any wall installation.
Note:
The most important thing to remember when mounting this Rough-In Box
is that the mounting tabs must be mounted flush against the outside of the
sheetrock. This step determines whether or not the mounting stud is notched
(cutout-out to fit the Rough-In Box).
Installing the CB-MVP-WCS52
The CB-MVP-WCS52 Rough-In Box is 10 inches (25.40cm) wide at its widest
dimension (wider than the bezel of the Wall Charging Station), and is only
intended for pre construction installations (FIG. 1). Refer to SP5966-01 for
detailed dimensions and installation specifications (see reverse)
The Rough-In Box is used in conjunction with the Wall Charging Station’s plastic
back box.
The Rough-In Box must be located behind 3/8" (0.95cm) to 3/4" (1.91cm) of wall/
mounting surface material.
The Rough-In Box bears a wing on each corner which is intended to bridge gaps
between studs and/or spacers. These wings may be bent carefully in order to fit
a particular gap, but may not be so bent as to allow the box to hang in a vertical
position.
Once placed in the desired position, put at least one screw through each wing
into the adjoining stud or spacer to secure it.
The interior of the Rough-In Box contains a set of holes on either side, as well as
top and bottom, for standard 1/4-inch screws. Use these holes to anchor the box
to its adjoining studs or spacers.
Note
: Ensure that the Rough-In Box is flush with the 2x4 studs. Any overhang
will affect the installation of the covering sheetrock, as well as affect the
placement of the Plastic Back Box. The Rough-In Box has two sets of knockouts
in the top and bottom, one of the set for US wiring and one for international
wiring.
Note
: Make sure that the power cable has been pulled through the Rough-In
Box by the resident electrician before continuing the installation.
After completing the installation of the Rough-In Box, install sheet rock or other
wall material over the box, cut a hole matching the size of the inside diameter in
the sheet rock, and clean out all dust before proceeding with the installation of
the plastic back box.
CB-MVP-WCS52 (FG037-11) Specifications
Dimensions (HWD):
• 5 11/16" x 8 3/8" x 1 1/2"
• 144.4 mm x 212.2 mm x 38.1 mm
Certifications
• UL 508A
FIG. 1
Typical CB-MVP-WCS52 Installation
Install front surface of
Rough-In Box flush with
surface of wall stud
FIG. 2
Installation of Wall Unit