background image

Quick Start Guide

MXD-2000XL-PAN

 

20.3" Modero X Series

®

 Panoramic Wall Mount Touch Panel

Overview

The MXD-2000XL-PAN 20.3" Modero X Series

®

 Panoramic Wall Mount Touch Panels 

feature a beautiful, panoramic capacitive multi-touch screen that provides users access to 
multiple applications with minimal navigation. It is hardware-ready for support of Near Field 
Communication™ (NFC) Technology to allow integration with NFC capable personal 
devices. The panoramic design offers the ability to perform multiple functions simultaneously. 
The MXD-2000XL-PAN is available in Portrait and Landscape layouts:      

Product Specifications 

Note: The MXD-2000XL-PAN-P-NC (FG5968-33) and MXD-2000XL-PAN-L-NC 
(FG5968-34) No Comm touch panels do not have camera, microphone, or NFC capability. 
These otherwise have all of the functionality of the MXD-2000XL-PAN panels.

MXD-2000XL-PAN Installation

For more detailed installation instructions including important notes on thermal 

concerns with Rack and Wall installations, refer to the 

X-Series Touch Panels MXD/T-

2000-XL-PAN & MXD/T-1900 -PAN Instruction Manual

 (available to view/download 

from www.amx.com).

Detailed specifications drawings for the MXD-2000XL-PAN are available to download 

from www.amx.com.

The MXD-2000XL-PAN may be installed directly into a solid surface environment, using 
either solid surface screws or the included locking tabs for different mounting options. 
Once installed, the panel is contained within a clear outer housing known as the Backbox. 
The Backbox is removed to install it into a wall, or when using the optional Rough-In Box 
accessory (

FG039-15

).

Note: For typical mounting surfaces, such as drywall, use the locking tabs as the primary 
method for securing the Backbox to the surface. For thin walls or solid surfaces, use 
mounting screws (not included).

Installing the MXD-2000XL-PAN Into a Wall

The MXD-2000XL-PAN comes with a clear plastic Backbox (FIG. 2) designed to attach the 
panel to most standard wall materials. This Backbox has four locking tabs (2 on top, 2 on 
bottom) to help lock the Backbox to the wall. 

These locking tabs are only extended AFTER the Backbox is inserted into the wall.

When installing the Backbox, make sure that the assembly is in the correct position 

and in the correct place. Once the locking tabs are extended and locked into place, 
removing the Backbox may be difficult without having access to the back of the wall or 
causing damage to the wall. 

In order to ensure a stable installation of the MXD-2000XL-PAN, the thickness of the 

wall material must be a minimum of .50 inches (1.27cm) and a maximum of .875 
inches (2.22cm). The mounting surface should also be smooth and flat.

The Backbox also has four slots for accepting the temporary mounting posts mounted on 
the back of the device.  

Installing the Backbox

Since the cutout for the Backbox is off-center from the edges of the touch panel, use the 
included Installation Template (

68-5968-01

) to ensure proper placement. The template is 

marked on one side with directions for both landscape and portrait installations to ensure that 
the touch panel and Backbox are properly aligned.

WARNING: Using the Installation template to select the final placement of the Backbox is 
highly recommended. The outside edges of the template are the same dimensions as the 
touch panel, which allows you to troubleshoot possible conflicts with wall edges, doors, and 
other potential obstacles.

1. Prepare the area by removing any screws or nails from the drywall before beginning the 

cutout process.

2. After ensuring proper placement, cut out the mounting surface for the Backbox, using the 

(included) Installation Template as a guide.

CAUTION: Making sure that the actual cutout opening is slightly smaller than the pro-
vided dimensions is highly recommended. This provides a margin of error if the opening 
needs to be expanded. Too little wall material removed is always better than too much.

3. Thread the incoming power and Ethernet wiring from their terminal locations through the 

surface opening (see FIG. 4 on reverse). 

Leave enough slack in the wiring to accommodate any re-positioning of the panel. 

 

4. Remove any knockouts as needed on either long dimension of the Backbox to facilitate 

incoming wiring and pull the wiring through the resultant holes.

5. Push the Backbox into the wall opening. Insure that the locking tabs lie flush against the 

Backbox.

6. Extend the locking tabs on the sides of the Backbox by tightening the screws inside the 

box until snug. Apply enough pressure to the screw head to keep the box flush with the 
wall: this ensures that the locking tabs will tighten up against the inside of the wall.

7. For additional strength, #4 mounting screws (not included) may be secured through the 

mounting holes located at the left and right sides of the panel (FIG. 4). 

In order to prevent damage to the touch panel, make sure that these are flush with the 
Backbox.

8. Insert each connector into its corresponding location along the back of the device. 
9. Test the incoming wiring by attaching the panel connections to their terminal locations 

and applying power. Verify that the panel is receiving power and functioning properly to 
prevent repetition of the installation. 

Remove power before continuing with the installation.
Note: Do not disconnect the cables from the touch panel. The panel must be installed 
with the cables attached before being inserted into the drywall.

Portrait

MXD-2000XL-PAN-P

FG5968-05

Landscape

MXD-2000XL-PAN-L

FG5968-11

FIG. 1  

MXD-2000XL-PAN-P/L (Portrait and Landscape)

MXD-2000XL-PAN Specifications

Dimensions (HWD) 

• Landscape: 9 1/2" x 20 3/8" x 11/16" (242mm x 519mm x 19mm)
• Portrait: 20 3/8" x 9 1/2" x 11/16" (519mm x 242mm x 19mm)

Weight

9.1 lbs (4.13 Kg)

Power Consumption

• Full-On: 32W (12 VDC, 2.7 A)
• Standby: 3.10 W (12 VDC, 0.3 A)
• Start-Up Inrush Current: 4.0 A for 80 µsec

External Power 
Supply Required 

Requires one of these AMX power sources (not included):
• PSN4.4 Power Supply, 4.4 A, 3.5 mm Phoenix, 13.5 VDC 

(FG423-45)

• MXA-MPL Modero X Series Multi Preview Live (FG5968-10)
• MXA-MP Modero X Series Multi Preview (FG5968-20)

Certifications

• UL 60950-1
• FCC Part 15 Class B
• C-Tick CISPR 22 Class B
• CE EN 55022, EN 55024 and EN 60950-1
• IEC 60950-1
• IC
• IEC/EN-60950
• RoHS/WEEE compliant

Environmental

• Temperature (Operating): 32° F to 104° F (0° C to 40° C)
• Temperature (Storage): 4° F to 140° F (-20° C to 60° C)
• Humidity (Operating): 20% to 85% RH
• Humidity (Storage): 5% to 85% RH
• Power ("Heat") Dissipation:

On: 109.2 BTU/hr
Standby: 10.6 BTU/hr

Included Accessories

• Locking 2-pin Phoenix mate (41-0002-SA)
• MXA-USB-C, USB Port Cover Kit (FG5968-18)
• MXA-CLK, Modero X Series Cleaning Kit (FG5968-16)
• Installation Template 20.3" (68-5968-01)

Sleep Button

NFC Sensor

Sleep

NFC

Button

Sensor

MXD-2000XL-PAN-P

MXD-2000XL-PAN-L

FIG. 2  

MXD-2000XL-PAN Backbox

FIG. 3  

MXD-2000XL-PAN (Landscape)

Locking Tabs

Locking Tabs

Temporary Mounting Posts

Temporary Mounting Posts

Backbox

Backbox knockouts (X8)

Locking tabs (X4)

Reviews: