Appendix B – Programmer’s Interface for System Diagnostics
107
Instruction Manual – HDMI-UTPRO-0808
Component Identity Settings
Detailed information for a single system component can be specified by using its identity (
i
) number setting
(
i0
through
i5
) in the following table. Minimal information for all five components can be specified by using the
identity number
i0
.
* In the case of the HDMI UTPro, “Boards” refers to the internal structure of the enclosure.
Default Settings
At system boot, the ~
scrv0i1!
setting is displayed (FIG. 70 on page 108).
If the verbosity setting is omitted, the verbosity level will be the lowest (
v0
).
The component setting
must
be included; otherwise, entering any of the verbosity settings alone will result in
a display equivalent to
v0i0
.
If both settings are omitted during a query (
~scr!
), the information displayed will be at the lowest verbosity
level for all components (
v0i0
Using BCS to Access System Diagnostic Information
Instructions are provided for accessing the lowest level of verbosity for all components and for accessing a specific level
of verbosity for a specific component.
To access the lowest level of verbosity for all components:
1.
Enter
~scr!
or
~scrv0i0!
Note:
Either of these commands provides a “menu” of the identity numbers and their corresponding
components (FIG. 65
Only one verbosity setting and one component setting can be entered in a command. The order in which the verbosity
and component identity settings are entered is interchangeable.
To access a specific level of verbosity for a specific component:
1.
Enter
~scr
(to access the splash screen).
2.
Enter the verbosity level setting
v#
and the component’s identity setting
i#
.
Either may be specified first.
3.
Enter
!
(to send the command).
Example
~scrv3i4!
or
~scri4v3!
(Either displays the highest level of detail for the Hardware / Boards.)
Component
Identity Number
All Components
i0
Enclosure
i1
Storage Blocks
i2
Communication Interfaces
i3
Hardware / Boards*
i4
VM Configuration
i5